| 2005-09-13 00:00:00 | BUILDING REVIEW THIRD CHECKLIST: |
| | 1- OPENINGS FROM THE GARAGE DIRECTLY |
| | INTO A ROOM USED FOR SLEEPING PURPOSES |
| | IS NOT ALLOWED. SEC. 411.2.8 FBC 2001. |
| | "THEATER" ROOM NEXT TO THE GARAGE IS SET |
| | UP AS A BEDRM. THERE IS A CLOSET IN THE |
| | ROOM AND ELECTRICAL PLAN SHOWS SMOKE |
| | DETECTORS IN AND OUT OF THE ROOM WHEN |
| | REQUIRED FOR SLEEPING ROOMS. REVISE AS |
| | REQUIRED. |
| | |
| | 2- NEED A COMPLETE BATHROOM WITH DOOR |
| | THAT ALLOWS 29" MIN. CLEAR OPENING AS |
| | REQUIRED BY SEC. 11-11 FBC 2001. |
| | |
| | 3- PRODUCT APPROVALS FOR DOORS/WINDOWS |
| | SUBMITTED ARE FOR IMPACT GLAZING. THIS |
| | HOUSE IS SUPPOSED TO HAVE NON-IMPACT |
| | GLAZING. PROVIDE CORRECT PRODUCT |
| | APPROVAL FOR: |
| | A) FRENCH DOORS. |
| | B) FIXED WINDOWS. |
| | C) SINGLE HUNG WINDOWS. |
| | D) SLIDING GLASS DOORS |
| | E) CASEMENT WINDOWS. |
| | |
| | 4- NEED TO SPECIFY SAFETY GLASS FOR |
| | WINDOWS AT HER BATH BY THE WHIRPOOL. |
| | SEC. 2405.2.1 FBC 2001. INFORMATION |
| | SUBMITTED WAS FOR IMPACT GLASS. THAT'S |
| | WHY THIS COMMENT WAS NOT ADDRESSED ON |
| | PREVIOUS CHECKLIST. |
| | |
| | 5- NEED RECORDED NOTICE OF COMMENCEMENT. |
| | |
| | 6- PROVIDE COMPLETE SPECS FOR BBQ HOOD |
| | FOR EXTERIOR USE AND SPECS FOR SPECIFIC |
| | GRILL TO BE INSTALLED. |
| | |
| | 7- PROVIDE COPY OF PAID IMPACT FEES |
| | RECEIPT THAT CORRESPONDS TO THIS HOUSE. |
| | RECEIPT SUBMITTED IS FOR ANOTHER HOUSE. |
| | |
| | 8- A) PROVIDE COMPLETE UL LISTING AND |
| | SPECS FOR TWO SIDED FIREPLACE AS SHOWN |
| | ON PLANS. INFORMATION SUBMITTED DOESN'T |
| | MATCH PLANS. |
| | |
| | B) PROVIDE COMBUSTION AIR CALCULATIONS |
| | FOR VENTLESS FIREPLACE FOR MECHANICAL |
| | PLANS EXAMINER REVIEW. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT (561)805-6712. |
| | |
| | |
| | |