2005-08-24 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05051845
 ADD: 7322 HORIZON DR
 CONT: WEATHERGUARD BUILDING PRO
 TEL: (561)790-5799
 FL BLDG CODE= 2001 FLORIDA BUILDING
 CODE*= WEST PALM BEACH AMENDMENTS
  
 FENCE & GATES REVIEW
 BUILDING : PROVISO
  
 SWIMMING POOL ACCESS GATES:
 424.2.17.1.8 ACCESS GATES, WHEN
 PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF
 ?424.2.17.1.1 THROUGH 424.2.17.1.7 AND
 SHALL BE EQUIPPED WITH A SELF-LATCHING
 LOCKING DEVICE LOCATED ON THE POOL SIDE
 OF THE GATE.WHERE THE DEVICE RELEASE
 IS LOCATED NO LESS THAN 54 INCHES FROM
 THE BOTTOM OF THE GATE, THE DEVICE
 RELEASE MECHANISM MAY BE LOCATED ON
 EITHER SIDE OF THE GATE AND SO PLACED
 THAT IT CANNOT BE REACHED BY A YOUNG
 CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAPS FROM THE OUTSIDE.GATES
 THAT PROVIDE ACCESS TO THE SWIMMING POOL
 MUST OPEN OUTWARD AWAY FROM THE POOL.
 THE GATES AND BARRIER SHALL HAVE NO
 OPENING GREATER THAN1/2 INCH WITHIN 18
 INCHES OF THE RELEASE MECHANISM.
  