| Date |
Text |
| 2005-06-14 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 CHAPTER 1 |
| | |
| | 1. SHT P.2 SANITARY RISER DIAGRAMS DO |
| | NOT RELFECT THE FLOOR PLANS, NOR DO THEY |
| | MEET CODE REQUIREMENTS. CORRECT THE |
| | FOLLOWING: |
| | SECOND FLOOR RISER DIAGRAM: (MISLABELED |
| | AS FIRST FLOOR) |
| | A. WATER CLOSETS SHALL NOT BE TRAPPED. |
| | THE W/C HAS AN INTEGRAL TRAP. SECTION |
| | 1002.1. |
| | B. 11 FIXTURES SHOWN ON THE FLOOR PLAN, |
| | BUT ONLY 10 FIXTURES ON RISER DIAGRAM. |
| | SECTION 104.2.1. |
| | C. LAVS MISLABELD AS SINKS. SECTION |
| | 104.2.1. |
| | D. SHOWER, TUB, & W/C FIXTURES ARE NOT |
| | VENTED. SECTION 901.2.1. DOUBLE LAVS |
| | SHOULD BE CONNECTED BETWEEN THE W/C AND |
| | THE TUB ON THE BRANCH LINE TO CORRECT |
| | THIS CODE REQUIREMENT. SECTION 104.2.1. |
| | E. TUB NOT VENTED IN BATH #3. MAXIMUM |
| | DISTANCE FOR TRAP FROM VENT IS 6' AND |
| | TUB TRAP SCALES OUT TO 10'. TABLE 906.1. |
| | F. WASH MACHINE SHALL NOT DRAIN THRU THE |
| | HORIZONTAL WET VENT OF THE BATHROOM |
| | FIXTURES. SECTION 909.1. - WASH MACHINE |
| | REQUIRES A STANDPIPE. SECTION 1002.1. |
| | WASH MACHINE REQUIRES A CLEANOUT 4' |
| | ABOVE THE FLOOR. SECTION 708.10. |
| | G. SHOWER IN BATH #3 NOT VENTED PER |
| | TABLE 906.1. |
| | FIRST FLOOR RISER DIAGRAM: |
| | A. LAVS MISLABELED AS SINKS. SECTION |
| | 104.2.1. |
| | B. KITCHEN SINK IN ISLAND, TRAP SHALL |
| | BE ABOVE THE FLOOR ON A RISER NOT UNDER |
| | THE SLAB AS SHOWN. SECTION 104.2.1. |
| | C. KITCHEN SINK RISER SHALL VTR |
| | DIRECTLY TO STAY IN THE WALL. SECTION |
| | 104.2.1. |
| | D. TUB IN BATHROOM NOT VENTED. SECTION |
| | 901.2.1. |
| | E. LAV IN POWDER ROOM SHALL BE |
| | CONNECTED TO STACK RISER, NOT UNDER SLAB |
| | AS SHOWN. SECTION 104.2.1. |
| | F. STACK RISER FOR LAV IN TUB BATHROOM |
| | SHALL VTR DIRECTLY TO STAY IN THE WALL. |
| | SECTION 104.2.1. |
| | 2. SEE RED LINE EXAMPLES OF CORRECTIONS |
| | TO THESE CODE REQUIREMENTS ON ONE SET OF |
| | PLANS. MAKE CORRECTIONS FOR EACH COMMENT |
| | AND RESUBMIT FOR REVIEW. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |
| | |