| 2005-06-24 00:00:00 | 1) 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 2) BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3)ALL |
| | INFORMATION/DRAWINGS/SPECIFICATIONS AND |
| | ACCOMPANYING DATA SHALL BEAR THE NAME |
| | AND SIGNATURE OF THE PERSON RESPON- |
| | SIBLE FOR THE DESIGN. SECTION 104.2.1 |
| | |
| | 4) PROVIDE ENERGY CALCULATIONS AND |
| | EQUIPMENT SIZING CALCULATIONS (MANUAL J) |
| | AS REQUIRED BY THE 2001 FLORIDA ENERGY |
| | EFFICIENTCY CODE FOR BUILDING CONSTRUC- |
| | TION. |
| | |
| | 5) 1707.4.4.2 TAPERED BUCKS: |
| | SHALL EXTEND BEYOND THE INTERIOR FACE |
| | OF THE WINDOW OR DOOR FRAME SUCH THAT |
| | FULL SUPPORT OF THE FRAME IS SUPPORTED. |
| | |
| | 6) FBC 1005.4.5 (GLITCH AMENDMENTS JULY |
| | 1, 2003) REQUIRES AT LEAST ONE MEANS OF |
| | ESCAPE FROM A DWELLING WHEN SHUTTERED |
| | FOR IMPACT PROTECTION. THE MEANS OF |
| | ESCAPE SHALL BE WITHIN THE FIRST FLOOR |
| | OF THE DWELLING AND CAN NOT BE LOCATED |
| | IN A GARAGE. OCCUPANTS IN ANY PART OF |
| | THE DWELLING SHALL HAVE ACCESS TO IT |
| | WITHOUT HAVING TO PASS THROUGH A |
| | LOCKABLE DOOR NOT UNDER THEIR CONTROL. |
| | INDICATE HOW COMPLIANCE WILL BE |
| | ACHIEVED. |
| | |
| | 7) PROVIDE PRODUCT APPROVALS FOR |
| | DOORS/WINDOWS/SHUTTERS AND ROOFING |
| | MATERIALS.PRODUCT APPROVALS SUBMITTED |
| | WITH PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE |
| | AT WWW.FLORIDABUILDING.ORG. PRODUCTS |
| | WITH STATEWIDE APPROVAL ARE REQUIRED TO |
| | BE SUBMITTED WITH A COVER SHEET THAT |
| | LISTS THE PRODUCT IDENTITY NUMBER FROM |
| | THE STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 8) THE LOWEST BUILDING FLOOR ELEVATION |
| | AT THE PERIMETER OF A MONOLITHIC |
| | FOUNDATION AT HABITABLE AREAS AHALL BE A |
| | MINIMUM OF 4" ABOVE THE FINISH GRADE AT |
| | THE BUILDING PERIMETER.FBC 1804.1.7 WPB |
| | AMENDMENTS. |
| | |