| 2006-01-25 00:00:00 | DENIED |
| | |
| | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3.SUBMIT TWO COPIES OF ENERGY CALCS TO |
| | FOR THE 2004 FBC. |
| | |
| | 4.R319.1 LOCATION REQUIRED. |
| | IN AREAS SUBJECT TO DECAY DAMAGE AS |
| | ESTABLISHED BY TABLE R301.2(1) , THE |
| | FOLLOWING LOCATIONS SHALL REQUIRE THE |
| | USE OF AN APPROVED SPECIES AND GRADE OF |
| | LUMBER, PRESSURE TREATED OR |
| | DECAY-RESISTANT HEARTWOOD OF REDWOOD, |
| | BLACK LOCUST, OR CEDARS. |
| | 1. WOOD JOISTS OR THE BOTTOM OF A WOOD |
| | STRUCTURAL FLOOR WHEN CLOSER THAN 18 |
| | INCHES (457 MM) OR WOOD GIRDERS WHEN |
| | CLOSER THAN 12 INCHES (305 MM) TO THE |
| | EXPOSED GROUND IN CRAWL SPACES OR |
| | UNEXCAVATED AREA LOCATED WITHIN THE |
| | PERIPHERY OF THE BUILDING FOUNDATION. |
| | 2. ALL WOOD FRAMING MEMBERS THAT REST |
| | ON CONCRETE OR MASONRY EXTERIOR |
| | FOUNDATION WALLS AND ARE LESS THAN 8 |
| | INCHES (203 MM) FROM THE EXPOSED GROUND. |
| | |
| | 3. SILLS AND SLEEPERS ON A CONCRETE OR |
| | MASONRY SLAB THAT IS IN DIRECT CONTACT |
| | WITH THE GROUND UNLESS SEPARATED FROM |
| | SUCH SLAB BY AN IMPERVIOUS MOISTURE |
| | BARRIER. |
| | 4. THE ENDS OF WOOD GIRDERS ENTERING |
| | EXTERIOR MASONRY OR CONCRETE WALLS |
| | HAVING CLEARANCES OF LESS THAN 0.5 INCH |
| | (12.7 MM) ON TOPS, SIDES AND ENDS. |
| | 5. WOOD SIDING, SHEATHING AND WALL |
| | FRAMING ON THE EXTERIOR OF A BUILDING |
| | HAVING A CLEARANCE OF LESS THAN 6 INCHES |
| | (152 MM) FROM THE GROUND. |
| | 6. WOOD STRUCTURAL MEMBERS SUPPORTING |
| | MOISTURE-PERMEABLE FLOORS OR ROOFS THAT |
| | ARE EXPOSED TO THE WEATHER, SUCH AS |
| | CONCRETE OR MASONRY SLABS, UNLESS |
| | SEPARATED FROM SUCH FLOORS OR ROOFS BY |
| | AN IMPERVIOUS MOISTURE BARRIER. |
| | 7. WOOD FURRING STRIPS OR OTHER WOOD |
| | FRAMING MEMBERS ATTACHED DIRECTLY TO THE |
| | INTERIOR OF EXTERIOR MASONRY WALLS OR |
| | CONCRETE WALLS BELOW GRADE EXCEPT WHERE |
| | AN APPROVED VAPOR RETARDER IS APPLIED |
| | BETWEEN THE WALL AND THE FURRING STRIPS |
| | OR FRAMING MEMBERS. |
| | |
| | CLEARLY SHOW ON PLANS WHERE ROT |
| | RESISTANT WOOD WILL BE USED. |
| | |
| | 5.SUBMIT TWO ORIGONAL SIGNED AND |
| | SEALED SURVEYS.FS 472.025 |
| | |
| | 6.SUMBIT TWO COPIES OF PRODUCT |
| | APPROVALS FOR THE FOLLOWING; ALL NEW |
| | EXTERIOR DOORS AND WINDOWS, IMPACT |
| | PROTECTION, ROOFING, STRAPS AND |
| | TIEDOWNS. |
| | |
| | 7.ALL PRODUCT APPROVALS SUBMITTED |
| | SHALL HAVE THE FOLLOWING STATE PRODUCT |
| | APPROVAL ATTACHED. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 8.2004 EXISTING BUILDING CODE 301.5 |
| | A DESIGN PROFESSIONAL OR AN OWNER MUST |
| | ELECT ONE OR A COMBINATION OF LEVELS OF |
| | ALTERATION PURSUANT TO SECTIONS 303 , |
| | 304 AND 305 OF THIS CODE. |
| | |
| | 9.WINDOWS AT TUB LOCATIONS SHALL HAVE |
| | SAFETY GLAZING. R308.4 |
| | |
| | 10.INCLUDE ON PLANS A DOOR AND WINDOW |
| | SCHEDULE. |
| | |
| | 11.CLEARLY SHOW NEW AREAS AND AREAS OF |
| | NEW WORK ALONG WITH EXISTING ITEMS. |
| | |
| | 12.FBC 2004 106.3.4 RESERVED. SITE |
| | DRAWINGS. DRAWINGS SHALL SHOW THE |
| | LOCATION OF ALL NEW WORK, INCLUDING THE |
| | PROPOSED BUILDING OR STRUCTURE, AND OF |
| | ALL EXISTING MAN-MADE IMPROVEMENTS AND |
| | EVERY EXISTING SURVEY, OR OTHER SPECIAL |
| | SURVEY, PREPARED BY A QUALIFIED |
| | SURVEYOR. IF REQUIRED, SURVEYS SHALL BE |
| | PREPARED IN ACCORDANCE WITH PROVISIONS |
| | OF CHAPTERS 177 AND 472 FLORIDA |
| | STATUTES, AND RULE 61G17, FLORIDA |
| | ADMINISTRATIVE CODE. |
| | |
| | 13.PERMIT FEES ARE DUE, SEE ATTACHED |
| | INVOICE. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |