| Plan Review Notes For Permit 05051060 |
| Permit Number |
05051060 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-07-19 00:00:00 | 1) 704.2.1.4 CORRIDOR PARTITIONS, | | | SMOKE STOP PARTITIONS, HORIZONTAL EXIT | | | PART- ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | TABLE 803.3 | | | MINIMUM INTERIOR FINISH CLASSIFICATION | | | | | | R- CLASS C INTERIOR FINISH MATERIALS MAY | | | BE USED WITHIN A DWELLING UNIT. | | | CLASS C INTERIOR FINISH.FLAMESPREAD | | | 76-200, SMOKE DEVELOPED 0-450. |
|