| 2005-06-27 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT:05051005 |
| | ADD:743 BISCAYNE DR. |
| | CONT:ROY STEPHEN |
| | TEL: (561)659-5683 |
| | |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW 1ST |
| | ACTION:DENIED |
| | |
| | 1) BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 2) 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 3) PROVIDE ENERGY CALCULATIONS AND |
| | EQUIPMENT SIZING CALCULATIONS (MANUAL J) |
| | AS REQUIRED BY THE 2001 FLORIDA ENERGY |
| | EFFICIENTCY CODE FOR BUILDING CONSTRUC- |
| | TION. |
| | |
| | 4) PLEASE PROVIDE PRODUCT APPROVALS FOR |
| | THE FOLLOWING.NEW DOORS/WINDOWS,ROOFING |
| | MATERIALS, LENTIL PRODUCT APPROVALS |
| | SUBMITTED WITH PERMIT APPLICATION AFTER |
| | OCTOBER 1, 2003 ARE REQUIRED TO COMPLY |
| | WITH THE FLORIDA PRODUCT APPROVAL |
| | SYSTEM. FOR INFORMATION PLEASE SEE THE |
| | STATE WEBSITE ATWWW.FLORIDABUILDING.ORG. |
| | PRODUCTS WITH STATEWIDE APPROVAL ARE |
| | REQUIRED TO BE SUBMITTED WITH A COVER |
| | SHEET THAT LISTS THE PRODUCT IDENTITY |
| | NUMBER FROM THE STATE. IF THE PRODUCT |
| | DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 5) PLEASE SHOW A DETAIL DRAWING FOR THE |
| | NEW PARAPET CONSTRUCTION. |
| | |
| | 6) FBC 2309.6ACCESS TO ATTIC SPACE |
| | EACH ATTIC SPACE WITH A CLEAR HEIGHT OF |
| | 24" OR GREATER SHALL BE PROVIDED WITH AN |
| | INTERIOR ATTIC ACCESS OPENING NOT LESS |
| | THAN 20"X 36". |
| | |
| | 7)THE SURVEY SUBMITTED STATES THAT THIS |
| | LOCATION IN A 'C' ZONE HOWEVER ON THE |
| | PLANS SHEET A.O. STATES FLOOD ZONE AS |
| | 'A5'. ACCORDING TO OUR FLOOD MAP, THE |
| | LOCATION IS IN A 'C' ZONE.PLEASE CHANGE |
| | PLANS TO MATCH. |
| | |