| 2005-06-26 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05050970 |
| | ADD: 777 S FLAGLER/ 12 FL W |
| | CONT: CATALFUMO |
| | TEL: (561)307-4836 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 2) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE |
| | STOP PARTITIONS, HORIZONTAL EXIT PART- |
| | ITIONS, EXIT ENCLOSURES, AND FIRE |
| | RATED WALLS REQUIRED TO HAVE PROTECTED |
| | OPENINGS SHALL BE EFFECTIVELY AND |
| | PERMANETLY IDENTIFIED WITH SIGNS OR |
| | STENCILING IN A MANNER ACCEPTABLE TO THE |
| | AUTHORITY HAVING JURISDICTION. SUCH IDEN |
| | TIFICATION SHALL BE ABOVE ANY DECORATIVE |
| | CEILING CEILING AND IN CONCEALED SPACES. |
| | SUGGESTED WORDING" FIRE & SMOKE BARRIER |
| | PROTECT ALL OPENINGS". |
| | |
| | 3) HANDICAPPED ACCESSIBILITYIS MISSING |
| | AT DOOR# 1201, 1209B, 1222,1223 & 1255. |
| | 11-4.13.6 MANEUVERING CLEARENCES |
| | AT DOORS. MINIMUM MANEUVERING CLEARENCES |
| | AT DOORS THAT ARE NOT AUTOMATIC OR |
| | POWER-ASSISTED SHALL BE AS SHOWN IN |
| | FIG. 25. THE FLOOR OR GROUND AREA WITH |
| | IN THE REQUIRED CLEARENCES SHALL BE |
| | CLEAR & LEVEL. |
| | 11-4.1.6(2) DUTY TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL TO ALTERED |
| | AREAS SHALL BE DEEMED DISPROPORTIONATE |
| | TO THE OVERALL ALTERATION WHEN THE COST |
| | EXCEEDS 20 % OF THE COST OF THE ALTERA- |
| | TION TO THE PRIMARY FUNCTION AREA. |
| | (A)(I) AN ACCESSIBLE ENTRANCE |
| | (II) AN ACCESSIBLE ROUTE |
| | (III) AT LEAST ONE ACCESSIBLE REST- |
| | ROOM FOR EACH SEX OR A SINGLE |
| | UNISEX RESTROOM |
| | (IIII) ACCESSIBLE TELEPHONE |
| | (IV) ELEMENTS SUCH AS PARKING, STOR- |
| | AGE OR ALARMS. |
| | |
| | |
| | PRIMARY FUNCTION. A "PRIMARY FUNCTION" |
| | IS A MAJOR ACTIVITY FOR WHICH THE |
| | FACILITY IS INTENDED.AREAS THAT |
| | CONTAIN A PRIMARY FUNCTION INCLUDE, BUT |
| | ARE NOT LIMITED TO, OFFICES AND OTHER |
| | WORK AREAS IN WHICH THE ACTIVITIES |
| | OF THE PUBLIC ACCOMMODATION OR OTHER |
| | PRIVATE ENTITY USING THE FACILITY ARE |
| | CARRIED OUT. |
| | |
| | THESE ARE AREA OF CONTRACT THAT CAN BE |
| | BACKED OUT OF CONTRACT TO DETERMINE PER |
| | CENTAGES FOR DISPROPORTIONATE COST. |
| | |
| | MECHANICAL ROOMS, BOILER ROOMS, SUPPLY |
| | STORAGE ROOMS, EMPLOYEE LOUNGES OR |
| | LOCKER ROOMS, JANITORIAL CLOSETS, |
| | ENTRANCES,CORRIDORS, AND RESTROOMS ARE |
| | NOT AREAS CONTAINING A PRIMARY FUNCTION. |
| | |
| | ALTERATIONS TO AN AREA CONTAINING A |
| | PRIMARY FUNCTION: |
| | |
| | (1) ALTERATIONS THAT AFFECT THE |
| | USABILITY OF OR ACCESS TO AN AREA |
| | CONTAINING A PRIMARY FUNCTION |
| | INCLUDE, BUT ARE NOT LIMITED TO: |
| | |
| | (A) REMODELING MERCHANDISE DISPLAY |
| | AREAS OR EMPLOYEE WORK AREAS IN A |
| | DEPARTMENT STORE; |
| | |
| | (B) REPLACING AN INACCESSIBLE |
| | FLOOR SURFACE IN THE CUSTOMER SERVICE |
| | OR EMPLOYEE WORK AREAS OF A BANK; |
| | |
| | (C) REDESIGNING THE ASSEMBLY LINE |
| | AREA OF A FACTORY; OR |
| | |
| | (D) INSTALLING A COMPUTER CENTER |
| | IN AN ACCOUNTING FIRM. |
| | |
| | (2) FOR THE PURPOSES OF THIS |
| | SECTION, ALTERATIONS TO WINDOWS, |
| | HARDWARE, CONTROLS, ELECTRICAL |
| | OUTLETS, AND SIGNAGE SHALL NOT BE DEEMED |
| | TO BE ALTERATIONS THAT AFFECT THE |
| | USABILITY OF OR ACCESS TO AN AREA |
| | CONTAINING A PRIMARY FUNCTION. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |