| Plan Review Notes For Permit 05050638 |
| Permit Number |
05050638 |
|
| Review Stop |
Z |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-06-06 00:00:00 | 1. LOFT A-1 ON GROUND FLOOR DOES NOT | | | MEET THE SITE VISIBILITY TRIANGLE | | | STANDARD.THE GROUND FLOOR ENTRANCE | | | MUST BE RECONFIGURED TO PROVIDE BETTER | | | SITE VISIBILITY AT THE INTERSECTION. | | | | | | 2. MANY OF THE PARKING SPACES IN THE | | | GARAGE ARE NOT MEASURED CORRECTLY, | | | MEASUREMENTS FOR WIDTH MUST BE TAKEN | | | FROM SIDE OF SUPPORT BEAM AND LENGTH | | | MEASUREMENTS MAY NOT OVER LAP WHEN | | | PARKING SPACES FACE EACH OTHER. | | | | | | 3. GENERATOR DOORS MAY NOT SWING OUT | | | INTO MARKED PARKING SPACES. | | | | | | 4. THE SITE PLANS STILL REFER TO RETAIL | | | USES, THIS BUILDING IS A RESIDENTIAL | | | ONLY PROJECT. | | | | | | 5. MISSING PAGES A1.02, A1.03. A1.04. | | | | | | 6. SITE DATA MUST BE PROVIDED FOR EACH | | | INDIVIDUAL BUILDING, SMALL CAR PARKING | | | NUMBERS NEED TO BE INCLUDED. | | | | | | 7. STATE ON PLANS THAT APPLICANT WILL | | | COMPLY WITH FUTURE CMUD STREETSCAPE | | | PLAN. |
|