Plan Review Notes
Plan Review Notes For Permit 05050549
Permit Number 05050549
Review Stop B
Sequence Number 1
Notes
Date Text
2005-08-18 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05050549
 ADD: 911 PASEO ANDORRA
 CONT: O/B ORDONEZ, SANTANDER
 TEL: (561)655-6119
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 2) 471.023 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ENGINEER
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ENGINEERING SERVICES, SHALL INCLUDE THE
 CERTIFICATE OF AUTHORIZATION NUMBER.
 ADD THE NUMBER TO EACH SHEET.THIS MAY
 BE ADDED BY HAND.
  
 3) IN ADDITION TO SIGNING, SEALING AND
 DATING EACH PAGE OF THE PLANS, THE
 ENGINEER IN RESPONSIBLE CHARGE MUST
 LEGIBLY INDICATE IN A TITLE BLOCK THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 PLAN SHEET. 61G15-23.002 F.A.C.
  
 4) FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH (140, 3 SECOND
 GUST)
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 5) PLANS INDICATE A 16" WIDE FOOTING BY
 12" DEEP. THE MINIMUM WIDTH IS 18", ALSO
  
 INDICATED IS A DOUBLE WIDE BRICK KNEE
 WALL, NO INDICATION OF A CONTINIOUS LOAD
 PATH, REINFORCMENT, TO ANCHOR THE
 PROPOSED ADDITION. PROVIDE A CONTINIOUS
 LOAD PATH FROM THE FOUNDATION THROUGH TO
 THE RAFTERS.PROVIDE THE UPLIFT FOR THE
 RAFTERS, MAGNITUDE OF FORCES TO BE
 RESSITED, UPLIFT, GRAVITY AND LATERAL
 LOADS. 1606.6.1.3.
 1606.1.3 ANCHORAGE AGAINST OVERTURNING,
 UPLIFT AND SLIDING. STRUCTURAL
 MEMBERS AND SYSTEMS, AND COMPONENTS AND
 CLADDING IN A BUILDING OR STRUCTURE
 SHALL BE ANCHORED TO RESIST WIND-INDUCED
 OVERTURNING, UPLIFT AND SLIDING AND TO
 PROVIDE CONTINUOUS LOAD PATHS FOR THESE
 FORCES TO THE FOUNDATION.WHERE A
 PORTION OF THE RESISTANCE TO THESE
 FORCES IS PROVIDED BY DEAD LOAD, THE
 MINIMUM DEAD LOAD LIKELY TO BE IN PLACE
 DURING A DESIGN WIND EVENT SHALL BE
 USED.
  
 6) PLANS TO INDICATE TERMITE TREATMENT
 FOR SOIL.1816.1.4 IF SOIL TREATMENT IS
 USED FOR SUBTERRANEAN TERMITE
 PREVENTION, CHEMICALLY TREATED SOIL
 SHALL BE PROTECTED WITH A MINIMUM 6 MIL
 VAPOR RETARDER TO PROTECT AGAINST
 RAINFALL DILUTION.IF RAINFALL OCCURS
 BEFORE VAPOR RETARDER PLACEMENT,
 RETREATMENT IS REQUIRED.ANY WORK,
 INCLUDING PLACEMENT OF REINFORCING
 STEEL, DONE AFTER CHEMICAL TREATMENT
 UNTIL THE CONCRETE FLOOR IS POURED,
 SHALL BE DONE IN SUCH MANNER AS TO AVOID
 PENETRATING OR DISTUBING TREATED SOIL.
  
 7) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED, PLANS
 DO NOT INDICATEA VAPOR BARRIER BEHIND
 THE DURA ROCK.
  
 8) PLANS DO NOT INDICATE HOW A WATER
 TIGHT SEAL BETWEEN THE 2X6 SILL AND
 BRICK.
  
 9) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 10) PROVIDE SLOPE FOR ROOF.
  
 11) RAFTER ATTACHMENT TO EXISTING
 BUILDING DOESN'T INDICATE HOW LEDGER IS
 TO BE ANCHORED AND INTO WHAT TYPE OF
 EXISSTING CONSTRUCTION. NOR DOES THE
 PLANS INDICATE WHAT TYPE OF DEVISE WILL
 ANCHOR THE RAFTER END TO THE LEDGER.
  
 12)PLANS DO NOT INDICATE THE END WALL
 SECTION, OR IF THE ROOF LINE HAS A SIDE
 OVERHANG?
  
 13) PLANS DO NOT INDICATE HOW THE
 EXISTING BATHROOMS ARE GOING TO BE
 VENTILATED, NOW THAT THERE WILL BE NO
 VENTILATION TO THE EXTERIOR?
  
 14) NO ELECTRICAL OR MECHANICAL
 INDICATED.
  
 15) PLANS INDICATE USE OF 8" BLACKET
 INSULATION AS OPTIONAL, SEE 13-604.1.C.1
 ADDITIONS. ALL ROOF/CEILINGS SHALL BE
 INSULATED TO THE MINIMUM R-VALUE GIVEN
 ON TABLE 6C-1 OF FORM 600C FOR THE TYPE
 OF CONSTRUCTION USED IN THE ADDITION.
  
 16) TABLE 2307.6B* REQUIRES 19/32" ROOF
 SHEATHING. FOOTNOTE (6) IN NO CASE SHALL
 ANY ROOF SHEATHING BE LESSTHAN 32/16
 19/32" WOOD STRUCTURAL PANELS IN SPANS
 16" OR MORE.
  
 17) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  
  