2005-07-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05050466
 ADD: 4440 BEACON CIR
 CONT: ANDERSON-MOORE
 TEL: (561)753-7400
 *= 2001 FLORIDA BUILDING CODE * WEST
 PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 1)PROVIDENOC RECORDED WITH THE CLERK OF
 COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) SHEETT INDICATES THIS TO BE A TYPE V
 UNPROTECTED BUILDING. SHEET 4 DETAIL "A"
 INDICATES THE WALL SUB-SHEATHING TO BE
 5/8" CDX PLYWOOD, TYPE V CONSTRUCTION
 DOES NOT HAVE COMBUSTIBLE WALLS.
  
 3)STUCCO VENNER WALLS REQUIRE A TERMITE
 INSPECTION ZONE: 1403.1.6 IN ORDER TO
 PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION,CLEARANCE BETWEEN
 EXTERIOR WALL COVERINGS(STUCCO) AND
 FINAL EARTH GRADE ON THEEXTERIOR OF A
 BUILDING SHALL NOT BE LESS THAN 6 INCHES
 (152 MM).
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026