| Plan Review Notes For Permit 05050466 |
| Permit Number |
05050466 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-07-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05050466 | | | ADD: 4440 BEACON CIR | | | CONT: ANDERSON-MOORE | | | TEL: (561)753-7400 | | | *= 2001 FLORIDA BUILDING CODE * WEST | | | PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1)PROVIDENOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) SHEETT INDICATES THIS TO BE A TYPE V | | | UNPROTECTED BUILDING. SHEET 4 DETAIL "A" | | | INDICATES THE WALL SUB-SHEATHING TO BE | | | 5/8" CDX PLYWOOD, TYPE V CONSTRUCTION | | | DOES NOT HAVE COMBUSTIBLE WALLS. | | | | | | 3)STUCCO VENNER WALLS REQUIRE A TERMITE | | | INSPECTION ZONE: 1403.1.6 IN ORDER TO | | | PROVIDE FOR INSPECTION FOR TERMITE | | | INFESTATION,CLEARANCE BETWEEN | | | EXTERIOR WALL COVERINGS(STUCCO) AND | | | FINAL EARTH GRADE ON THEEXTERIOR OF A | | | BUILDING SHALL NOT BE LESS THAN 6 INCHES | | | (152 MM). | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|