| 2005-05-16 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05050463 |
| | ADD: 4500 S DIXIE HWY. |
| | CONT: ABSOLUTE STORM & SECURITY |
| | TEL: (772)215-5203 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) FL BLD CODE 104.2.1.2* |
| | ADDITIONAL INFORMATION REQUIRED, |
| | THE PERMIT APPLICATION IS NOT CLEAR, AS |
| | TO THE WORK THAT IS TO BE PREFORMED. |
| | THE APPLICATION INDICATES "STORM PANELS |
| | ON DOUBLE DOORS:, ARE THE STORM SHUTTERS |
| | TO BE APPLIED TO THE DOOR FACE AS A |
| | DIRECT MOUNT OR ARE THE STORM SHUTTERS |
| | BEING APPLIED TO THE SLAB AT GRADE AND |
| | WALL FACE ABOVE THE DOORS.SHEET 2 OF 5 |
| | INDICATES THE USE OF BUILD OUT MOUNT, |
| | AGAIN INDICATE IF THIS IS TO BE APPLIED |
| | TO THE DOOR OR WALL.ANCHORS INDICATED |
| | ARE CIRCLED FOR SOLID CONCRETE AND FOR |
| | HOLLOW CONCRETE BLOCK WHICH IS IT? |
| | |
| | 2)IF THE SHUTTERS ARE APPLIED TO THE |
| | WALL COVERING THE DOOR HOW DO YOU |
| | MAINTAIN EGRESS, ASSEMBLY OCCUPANCY? |
| | |
| | 3) THE EXTERIOR DOORS BEING COVERED WITH |
| | SHUTTERS NEVER HAVE BEEN PERMITTED AS |
| | STATED IN THE LETTER TO ANDERSON-MOORE |
| | CONSTRUCTION CORP. THIS WILL REQUIRE |
| | EITHER STATE WIDE PRODUCT APPROVAL WITH |
| | ATTACHED TEST REPORT OR FOR CUSTOM DOORS |
| | SITE SPECIFIC DRAWINGS AND CALCULATIONS |
| | FROM AN ARCHITECT OR ENGINEER. |
| | |
| | 4)PROVIDE STATEWIDE COVERSHEET. PRODUCT |
| | APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE |
| | REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 5)FL BLD CODE 2001 SECTION 103.6,* |
| | 1606.1.4,* 1707.4*& 3401.7.2.4. |
| | PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| | SCHEDULE SUMMARIZING & IDENTIFYING |
| | OPENING SIZES, STORY HEIGHTS, UNIT MARK |
| | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM |
| | BAR REINFORCING REQUIREMENTS, WALL PRES- |
| | SURE ZONES, SLAT TYPES, ETC., SHALL BE |
| | SUBMITTED AT TIME OF PERMIT APPLICATION |
| | TO FACILITATE PLAN REVIEW AND PERMIT |
| | ISSUANCE. |
| | |
| | 6) 1606.1.5 PROVIDE THE CORRECT MEAN |
| | ROOF HEIGHT.TAKEN FROM THE MIDPOINT |
| | (HEIGHT) OF THE ROOF.ADJUST SCHEDULES |
| | ACCORDINGLY. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |
| | |