| Notes |
| Date |
Text |
| 2005-05-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1. SHOW OPENING FOR WATER CLOSET. | | | MINIMUM 15" OFF THE WALL AND 15" OFF THE | | | SHOWER TO CENTERLINE OF FIXTURE. MINIMUM | | | 30" OPENING REQUIRED. SECTION 405.3.1. | | | 2. SHOW SIZE OF SHOWER STALL. MINIMUM | | | 900 SQUARE INCHES. MINIMUM 30" INSIDE | | | FINISH WIDTH. SECTION 417.4. | | | 3. SANT. RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN. ONLY ONE LAV SHOWN ON | | | THE RISER DIAGRAM, AND TWO LAVS ARE | | | SHOWN ON THE FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|