| Date |
Text |
| 2005-06-16 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | 1. ALL PLANS DESIGNED BY A PROFESSIONAL |
| | INTERIOR DESIGNER SHALL SHOW FIRM |
| | LICENSE NUMBER IN TITLE BLOCK OF EACH |
| | SHEET, DATE PREPARED FAC |
| | 61G1-16.004(2)(4) AND FS 481.2055 |
| | 2. THE PERSONAL SIGNATURE AND THE DATE |
| | THE SEAL AND SIGNATURE ARE AFFIXED SHALL |
| | APPEAR ON EACH SHEET. FAC 61G1-16.003 & |
| | FS 481.2055. |
| | 3. A DRINKING FOUNTAIN IS REQUIRED PER |
| | TABLE 403.1. |
| | 4. THE TOILET ROOM SHALL BE ACCESSIBLE. |
| | SHOW THE FOLLOWING FOR COMPLIANCE: |
| | FOR WATER CLOSET: |
| | A. CLEAR FLOOR SPACE 11-4.16.2 |
| | B. GRAB BARS 11-4.16.4 (SHOW HEIGHT) |
| | C. FLUSH CONTROLS 11-4.16.5 |
| | FOR LAV: |
| | A. HEIGHT & CLEARANCES 11-4.19.2 (SHOW |
| | CLEARANCE MEASURMENT) |
| | B. CLEAR FLOOR SPACE 11-4.19.3 |
| | C. EXPOSED PIPES & SURFACES 11-4.19.4 |
| | D. FAUCETS 11-4.19.5 |
| | 5. THERE HAVE BEEN TWO SHEETS LABELED AS |
| | P-1. PLEASE CLARIFY. SECTION 104.2.1. |
| | 6. FIRST P-1 WATER RISER DIAGRAM, THE |
| | WATER HAMMER ARRESTOR SHALL BE LOCATED |
| | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" |
| | NOT IN THE CEILING AS SHOWN. PDI-WH 201. |
| | - SHUT OFF VALVE REQUIRED FOR THE HOSE |
| | BIBB. SECTION 606.2(2). |
| | 7. FIRST P-1 SANT. RISER DIAGRAM, THE |
| | WASH MACHINE SHALL HAVE A STANDPIPE AND |
| | THE CLEANOUT SHALL INSTALLED 4' ABOVE |
| | THE FLOOR. SECTIONS 708.10 & 1002.1. |
| | 8. ENGINEER SHALL INDICATE THE |
| | CERTIFICATE OF AUTHORIZATION NUMBER OF |
| | THE ENGINEERING BUSINESS ON EACH SHEET. |
| | FAC 61G15-23.002(2) & FS 471.025 |
| | 9. A PROFESSIONAL ENGINEER SHALL SIGN |
| | HIS NAME AND AFFIX HIS SEAL TO ALL |
| | SHEETS. THE DATE THAT THE SIGNATURE AND |
| | SEAL IS AFFIXED SHALL BE ENTERED ON EACH |
| | SHEET. RULING BY FBPE STATES THAT |
| | INITIALS ARE NOT APPROVED AND THAT THE |
| | LEGAL SIGNATURE IS REQUIRED. FAC |
| | 61G15-23.002(1) & FS 471.025. |
| | 10. SEAL SHALL INPRESS ALL INFORMATION |
| | REQUIRED BY THE FLORIDA AMINISTRATIVE |
| | CODE AND THE FLORIDA STATUTES. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |