| 2005-06-17 00:00:00 | BUILDING PLAN REVIEW: FAILED |
| | |
| | |
| | 1 ALL |
| | INFORMATION/DRAWINGS/SPECIFICATIONS AND |
| | ACCOMPANYING DATA SHALL BEAR THE NAME |
| | AND SIGNATURE OF THE PERSON RESPON- |
| | SIBLE FOR THE DESIGN. SECTION 104.2.1 |
| | |
| | 2. THE FRENCH DOORS ARE NOT LISTED ON |
| | THE PERMIT APPLICATION. DRAWINGS SHOW |
| | INSTALLATION OF A TRIPLE FRENCH DOOR IN |
| | EXISTING RESIDENCE. SUBMIT FLORIDA |
| | PRODUCT APPROVAL FOR THE FRENCH DOORS. |
| | |
| | 3. IF THE FRENCH DOORS ARE NOT IMPACT |
| | RATED HURRICANE PROTECTION WILL BE |
| | REQUIRED.THESE CAN BE ADDED TO THIS |
| | PERMIT WITH SUBMITTAL OF FLORIDA PRODUCT |
| | APPROVALS FOR THE HURRICANE PANELS & |
| | PAYMENT OF ADDITIONAL FEES FOR THE COST |
| | OF THE PANELS (LABOR & MATERIALS. |
| | |
| | 4. DRAWINGS NOTE CONCRETE COLUMNS TO BE |
| | REMOVED BETWEEN THE DOOR & WINDOWS BEING |
| | REMOVED. NEED ENGINEERED DRAWING DETAIL |
| | SHOWING THE REMOVAL OF THE COLUMNS & |
| | DETAIL FOR THE FRAMING OF THE OPENING TO |
| | SUPPORT THE NEW FRENCH DOORS PER THE |
| | FBC. THESE CAN BE SUBMITTED ON 8 1/2" X |
| | 11" SIGNED & SEALED BY ENGINEER. NOTE: |
| | ENGINEER TO INCLUDE HIS TITLE BLOCK AS |
| | PER FAC 61G15-23.002. |
| | |
| | 5. THE PERMIT SAYS FLOOR & SCREEN PORCH. |
| | NO DRAWINGS HAVE BEEN SUBMITTED FOR THE |
| | SCREEN PORCH.THESE DRAWINGS MUST BE |
| | DONE BY AN ENGINEER AND SHOW COMPLIANCE |
| | WITH THE FBC 2001 & WIND OF 140 MPH FOR |
| | PALM BEACH COUNTY. |
| | 5. THE VALUE STATED APPEARS TO BE TOO |
| | LOW.CALCULATE THE TOTAL COST INCLUDING |
| | LABOR & MATERIALS. |
| | |