| 2005-05-11 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05041857 | | | ADD:2247 PBL BLVD | | | CONT:ANDREA CONSTRUCTION INC. | | | TEL: (561)795-1136 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW:1ST | | | ACTION:DENIED | | | | | | 1) SUBMIT PRODUCT APPROVALS FOR | | | (A)METAL ROOF (B)STRAPS AND TIE DOWNS. | | | | | | 2) FBC* F102.1 TYPE VI CONSTRUCTION IS | | | NOT ALLOWED IN A FIRE DISTRICT.THE GABLE | | | ENDIS CONSIDERED A WALL.BECAUSE | | | IT INCORPORATES PLYWOOD IT IS THEREFORE | | | OF TYPE VI CONSTRUCTION. PLEASE REMOVE | | | THE PLYWOOD AND REPLACE WITH | | | NON-COMBUSTIBLE. CHANGE PLANS TO COMPLY | | | | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 |
|