| Plan Review Notes For Permit 05041827 |
| Permit Number |
05041827 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-05-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS, AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | SECTION 104.2.1. | | | 2) WATER RISER DIAGRAMS APPEAR TO HAVE | | | AIR CHAMBERS AT THE LAV AND AT THE | | | SHOWER VALVE. AIR CHAMBERS ARE NOT | | | APPROVED. IF THESE ARE AIR HAMMER | | | ARRESTORS, PLEASE INDICATE AS MUCH ON | | | THE PLANS. IF THESE ARE AIR CHAMBERS, | | | THEY SHALL BE DELETED. SECTION 604.9 AND | | | PDI-WH 201. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|