| 2005-06-01 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1. SHT A-1.1 CLEAR FLOOR SPACE FOR | | | COFFEE AREA SINK SHALL EXTEND A MAXIMUM | | | OF 19" UNDERNEATH THE COUNTER. SECTION | | | 11-4.24.5. THE SINK SHALL BE CENTERED ON | | | THE 30" WIDTH OF THE CLEAR FLOOR SPACE. | | | SEE FIG. 32. | | | 2. SHT A-3.0 SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | A. HEIGHTS & CLEARANCES 11-4.19.2 | | | B. EXPOSED PIPES & SURFACES 11-4.19.4 | | | C. FAUCETS 11-4.19.5 | | | 3. SHT P-1 DOMESTIC WATER ISOMETRIC, THE | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | AND MANUF. INSTALL. INSTRUCTIONS. | | | 4. A DRINKING FOUNTAIN IS REQUIRED PER | | | TABLE 403.1. IF A DRINKING FOUNTAIN IS | | | PROVIDED IN THE COMMON AREA, PLEASE | | | INDICATE THE LOCATION ON THE PLANS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|