2005-06-01 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1. SHT A-1.1 CLEAR FLOOR SPACE FOR
 COFFEE AREA SINK SHALL EXTEND A MAXIMUM
 OF 19" UNDERNEATH THE COUNTER. SECTION
 11-4.24.5. THE SINK SHALL BE CENTERED ON
 THE 30" WIDTH OF THE CLEAR FLOOR SPACE.
 SEE FIG. 32.
 2. SHT A-3.0 SHOW COMPLIANCE WITH THE
 FOLLOWING:
 A. HEIGHTS & CLEARANCES 11-4.19.2
 B. EXPOSED PIPES & SURFACES 11-4.19.4
 C. FAUCETS 11-4.19.5
 3. SHT P-1 DOMESTIC WATER ISOMETRIC, THE
 WATER HAMMER ARRESTORS SHALL BE LOCATED
 NEAR THE FIXTURE IN AN "EFFECTIVE RANGE"
 NOT IN THE CEILING AS SHOWN. PDI-WH 201
 AND MANUF. INSTALL. INSTRUCTIONS.
 4. A DRINKING FOUNTAIN IS REQUIRED PER
 TABLE 403.1. IF A DRINKING FOUNTAIN IS
 PROVIDED IN THE COMMON AREA, PLEASE
 INDICATE THE LOCATION ON THE PLANS.
  