Plan Review Notes For Permit 05040948
Permit Number 05040948
Review Stop P
Sequence Number 1
Notes
Date Text
2005-06-03 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL CODE
 FBC-2001 BUILDING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. PLANS SHALL BE ROUTED TO DBPR HOTEL &
 RESTURANT DIVISION FOR REVIEW PRIOR TO
 RESUBMITTING TO THE CITY WPB FOR REVIEW.
 SUBMIT A MINIMUM OF 3 SETS OF PLANS
 STAMPED BY DBPR WITH THE TWO PAGE "WORK
 SHEETS" ATTACHED TO EACH SET. SECTION
 101.4.7.
 2. INDICATE IF FOOD WILL BE PREPARED ON
 SITE OR IF ALL FOOD WILL BE PREPACKAGED
 FOOD FOR COMSUMPTION. TO DETERMINE IF A
 GREASE INTERCEPTOR IS REQUIRED CONTACT
 RODNEY COMPO, ENVIRONMENTAL COMPLIANCE.
 (561) 473-4074, FAX (561) 659-7458, OR
 E-MAIL [email protected]. PLEASE SUBMIT HIS
 DETERMINATION WITH PLANS.
 3. SHT A-0.04 SEPARATE POOL PERMIT
 REQUIRED. SECTION 104.1.1.
 4. SHT A0.06 TUB & SHOWER DETAIL, SHOW
 MEASURMENTS FOR CONTROLS. SECTIONS
 11-4.20.5 & 11-4.21.5.
 5. SHTS A-2.01 & A-2.02 TOILET ROOMS.
 SHOW CLEAR FLOOR SPACE FOR EACH
 ACCESSIBLE FIXTURE. SHOW TURNING AREA IN
 EACH TOILET ROOM, NOT REQUIRED IN STALL.
 SECTION 11-4.22.3
 6. SHTS A-2.01 & A-2.02 SUBMIT
 CALCULATIONS FOR MINIMUM FACILITIES PER
 TABLES 1103.1 & 403.1 FOR ALL COMMON
 AREAS. SHOW THE SQUARE FOOTAGE OF EACH
 COMMON AREA ON THE FLOOR PLAN.
 7. SHT A-2.02 SINK IN EMPLOYEE BREAK
 ROOM SHALL COMPLY WITH SECTION 11-4.24
 AND ALL SUBSECTIONS. (FORWARD APPROACH
 IS REQUIRED MAXIMUM 19" UNDERNEATH THE
 SINK. SINK SHALL BE CENTERED ON THE 30"
 WIDTH OF THE CLEAR FLOOR SPACE).
 8. PER TABLE 403.1 A SERVICE SINK IS
 REQUIRED.
 9. SHTS A-2.10 & A-2.11 SEE COMMENT #5
 CONCERNING REQUIRED TURNING AREA.
 10. ALL RAIN WATER DOWNSPOUTS AND
 CONDENSATE SHALL DRAIN A MINIMUM OF 1FT
 FROM THE STRUCTURAL WALL. SECTION
 1503.4.4.
 11. SHT A-8.04 DETAIL #11 SHOW THE
 FOLLOWING TO SHOW COMPLIANCE: FOR THE
 W/C:
 A. HEIGHT 11-4.16.3
 B. GRAB BARS 11-4.16.4
 C. FLUSH CONTROLS 11-4.16.5
 LAV:
 A. HEIGHT & CLEARANCES 11-4.19.2
 B. EXPOSED PIPES & SURFACES 11-4.19.4
 C. FAUCETS 11-4.19.5
 DETAIL #10 SAME AS FOR DETAIL #11 PLUS
 URINAL:
 A. HEIGHT 11-4.18.2
 B. FLUSH CONTROLS 11-4.18.4
 DETAIL #5 SAME AS #11 EXCEPT FOR SECTION
 11-4.19.4 EXPOSED PIPES & SURFACES.
 12. SHT P-2.01 GENERAL NOTES:
 #2 GOVERNING CODE IS FBC-2001 NOT 2002
 OBC OR 2002 OHIO PLUMBING CODE. PLEASE
 CORRECT.
 #12 REVISIONS WILL BE REQUIRED FOR ALL
 CHANGES TO A SIGNED/SEALED/DATED SET OF
 PLANS.
 #27 AIR CHAMBERS ARE NOT APPROVED PER
 SECTION 604.9. DELETE FROM REFERENCE.
 #29 CONDENSATE SHALL BE PIPED
 SEPARATELY FROM THE BUILDING AND
 CONNECTED TO STORM, A CATCH BASIN OR TO
 DRYWELL/PLANTED AREA.
 13. SHT P-2.01 PIPING SCHEMATIC AT WATER
 HEATERS:
 A. 160 DEGREE TO AIR HANDLERS, SHOWS
 WATER GOING TO THE AIR HANDLERS, BUT NO
 RETURN. PLEASE CLARIFY SECTION 104.2.1.
 - A CHECK OF THE MECHANICAL PLANS DOES
 NOT SHOW 160 DEGREE WATER PIPED TO THE
 AIR HANDLERS. PLEASE SUBMIT A DETAIL AND
 MORE INFORMATION ON THIS SYSTEM. SECTION
 104.2.1.
 B. T&P DRAINAGE SHALL DRAIN TO A FLOOR
 SINK OR HUB DRAIN. FLOOR DRAINS ARE NOT
 APPROVED INDIRECT WASTE RECEPTORS.
 SECTIONS 802.3 & 802.3.2.
 C. DIELECTRIC UNIONS ARE NOT APPROVED
 FOR WATER PIPING USAGE. DIELECTRIC
 COUPLINGS SHALL BE USED.
 D. 2-1/2" STUB OUTS W/BY-PASS FOR
 FUTURE SOFTENER (HOT WATER ONLY) APPEARS
 TO BE ON THE COLD WATER INLET PIPING.
 PLEASE CLARIFY. SECTION 104.2.1.
 14. SHTS P-3.01, P-3.02, & P-3.03 SANT.
 RISER DIAGRAMS, TUBS AND SHOWERS REQUIRE
 A TRAP. SECTION 1002.1. - RISER DIAGRAMS
 DO NOT REFLECT THE FLOOR PLANS. PLEASE
 SUBMIT RISER DIAGRAMS IN AN ISOMETRIC
 FORM THAT REFLECT THE FLOOR PLAN, AND
 MEET CODE REQUIREMENTS. SHOW ALL PIPE
 SIZES, VENTS AND DFU FOR EACH RISER.
 SECTION 104.2.1.
 15. SUBMIT A BUILDING DRAIN SANITARY
 ISOMETRIC SHOWING ALL PIPE SIZES, DFU'S
 AS THEY ACCUMULATE IN THE SYSTEM, AND
 SHOW RISER LOCATIONS WITH RISER
 DESIGNATION NUMBERS. SECTIONS 104.2.1 &
 104.3.1.1.
 16. SHTS P3.04, P-3.05, & P-3.06 WATER
 RISER DIAGRAMS, FULL OPEN VALVES ARE
 REQUIRED ON THE BASE OF EVERY WATER
 RISER PIPE. SECTION 606.1(3).
 17. SUBMIT A WATER RISER DIAGRAM IN
 ISOMETRIC FORM FOR THE LAUNDRYAND ALL
 COMMON AREAS SHOWING ALL PIPE SIZES,
 VALVES, AND WATER HAMMER ARRESTORS,
 (WHERE REQUIRED BY SECTION 604.9).
 18. SUBMIT A WATER RISER DIAGRAM IN
 ISOMETRIC FORM FOR THE WATER
 DISTRIBUTION SYSTEM SHOWING THE LOCATION
 OF THE WATER ENTERING THE BUILDING, ALL
 PIPING NOT SHOWN ON RISERS, ALL PIPE
 SIZES, WATER HAMMER ARRESTORS, LOCATION
 OF WATER RISERS CONNECTING TO
 DISTRIBUTION LINE WITH RISER DESIGNATION
 NUMBERS ECT. SECTIONS 104.2.1 AND
 104.3.1.1.
 19. SUBMIT A CONDENSATE RISER DIAGRAM
 SHOWING ALL PIPE SIZES, MATERIAL, AND
 TERMINATION POINT. SECTIONS 104.2.1. &
 104.3.1.1.
 20. THE FOLLOWING INFORMATION IS
 REQUIRED FOR A GAS PERMIT:
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE IF BEING USED.
 C. TYPE OF GAS, (LP OR NATURAL)
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34).
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 F. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 I. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 J. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]