| 2005-06-01 00:00:00 | BUILDING REVIEW CHECKLIST: |
| | 1- NEED RECORDED NOTICE OF COMMENCEMENT. |
| | |
| | 2- SHEET T1: A) UPDATE GENERAL NOTES. |
| | SEE COMMENTS ON PLANS AND RETURN |
| | REVIEWED SET AFTER CORRECTIONS ARE DONE |
| | TO ORIGINAL DRAWINGS TO EXPEDITE REVIEW. |
| | |
| | 3- DESIGN PARAMETERS: CLARIFY WHERE IS |
| | THE BASIC VELOCITY PRESSURE TAKEN FROM. |
| | SEE SEC. 1606 FBC 2001. |
| | ALSO, CLARIFY WHY THE MIN. SOIL BEARING |
| | PRESSURE IS -NA? |
| | |
| | 4- PROVIDE COMPLETE INFORMATION FOR |
| | STORM SHUTTERS OR APPLY FOR A SEPARATE |
| | PERMIT. |
| | |
| | 5- SHEET A1: A) COLUMNS AT LANAI WERE |
| | KEYED WRONG. THEY SHOULD BE C4 NOT C2. |
| | SEE COMMENTS ON PLANS & REVISE AS REQ'D. |
| | |
| | B) DETAIL 4 DOESN'T MATCH FOOTING SHOWN |
| | ON PLAN BETWEEN BEDROOM #2 AND GARAGE. |
| | REVISE AS REQUIRED. |
| | |
| | 6- SHEET A2: A) SPECIFY SAFETY GLASS FOR |
| | WINDOWS AT HER BATH, HIS BATH AND LIVING |
| | ROOM. SEC. 2405.2 FBC 2001. |
| | |
| | B) CLARIFY NOTE #6. ARE WINDOWS AND |
| | DOORS HAVING IMPACT GLAZING OR STORM |
| | SHUTTERS?. SEE NOTE UNDER DESIGN |
| | PRESSURES CHART AND REVISE AS REQ'D. |
| | |
| | 7- PROVIDE COMPLETE BBQ SPECS STATING |
| | THAT GRILL IS DESIGNED TO BE INSTALLED |
| | IN PORCH OR LANAI. SEC. 2808 FBC 2001. |
| | |
| | 8- SHEET A3: A) REVISE/UPDATE TRUSS |
| | ANCHOR SCHEDULE. SEE LATEST CATALOGUE |
| | WHICH WAS REVISED TO COMPLY WITH SEC. |
| | 1609.4.3 FBC 2001. PROVIDE COMPLETE |
| | ENGINEERING CALCULATIONS SHOWING |
| | COMPLIANCE WITH SEC. 1609.4.3 FBC 2001 |
| | FOR FASTENERS TYPE AND SPACING THAT |
| | DIFFER FROM THOSE TESTED AND PUBLISHED |
| | BY THE MANUFACTURER. SEC. 104.2.1.2 CITY |
| | AMENDMENTS TO FBC 2001. |
| | |
| | B) CONNECTOR THD210 IS A WOOD TO WOOD |
| | CONNECTOR. NEED TO SPECIFY WOOD TO |
| | MASONRY HANGER. SEE CATALOGUE FOR PROPER |
| | MASONRY CONNECTORS AND REVISE AS |
| | REQUIRED. |
| | |
| | C) SPECIFY CONNECTOR FOR TRUSS GIRDER |
| | END AT INTERSECTION OF MASTER BEDROOM |
| | AND CLUB ROOM CORNER. SEE PLANS. |
| | |
| | 9- APPLY FOR LOCAL PRODUCT APPROVAL FOR |
| | CORNER SLIDING GLASS DOORS. DADE COUNTY |
| | NOA ALONE IS NOT AUTOMATICALLY A FLORIDA |
| | PRODUCT APPROVAL. FILL OUT APPLICATION |
| | FOR LOCAL PRODUCT APPROVAL. SEE |
| | WWW.FLORIDABUILDING.ORG. |
| | |
| | 10- WINDOW AND DOOR MULLIONS: CLEARLY |
| | INDICATE SIZE AND ANCHOR TYPE ACCORDING |
| | TO ASSEMBLY TO VERIFY COMPLIANCE WITH |
| | DESIGN PRESSURES. SEC. 104.2.1.2 CITY |
| | AMENDMENTS TO FBC 2001. |
| | |
| | 11- DADE COUNTY NOA SUBMITTED FOR |
| | CASEMENT WINDOWS DOESN'T MATCH NOA |
| | LISTED ON FLORIDA PRODUCT APPROVAL COVER |
| | PAGE. REVISE AS REQUIRED. |
| | |
| | 12- PROVIDE COMPLETE LISTING FOR |
| | FIREPLACE SHOWING COMPLIANCE WITH UL 127 |
| | REQUIREMENTS. SEC. 2806 FBC 2001. |
| | |
| | *** PLEASE DON'T STAPLE PRODUCT |
| | APPROVALS TO PLANS. IT WILL EXPEDITE |
| | REVIEW PROCESS AND HANDLING OF PLANS. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT (561)805-6712. |
| | |