Text |
| 2005-03-31 00:00:00 | **** UNSAT **** | | | | | | 1)NOTE: PLEASE SEE PLANS INDICATE A | | | DRYER, HOWEVER PANEL SCHEDULE AND LOAD | | | CALCULATIONS DO NOT SHOW. | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE | | | INDICATES DISHWASHER ON A 2P20A BRKR FOR | | | OCP.? | | | IS THIS PART OF DISPOSAL/DISHWASHER? | | | | | | 3)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING TO CONDENSING UNITS. | | | PLEASE ALSO SEE 3-#6'S TO COND UNIT. IS | | | THIS 2-#6'S AND ONE #10? | | | PLEASE SEE CONDUIT FILL FOR SCHEDULE 80 | | | PVC. PLEASE SEE EUIPMENT GROUNDING PER | | | 250.122 | | | | | | 4)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 5)NOTE: PLEASE SEE NUMEROUS BRANCH | | | CIRCUITS WITH 15A OCP ON #12 AWG. THIS | | | IS OK AND DOES MEET CODE, HOWEVER PLEASE | | | VERIFY. IF SHOWN, THEN THIS MUST BE | | | DONE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|