Plan Review Notes
Plan Review Notes For Permit 05031461
Permit Number 05031461
Review Stop B
Sequence Number 1
Notes
Date Text
2005-04-26 00:00:00BUILDING REVIEW CHECKLIST:
 1- SHEET A-2: A)KEYED DETAILS DON'T
 MATCH. THERE IS NOT SHEET A-13. REVISE
 ALL KEYED DETAILS TO MATCH SPECIFIC
 DETAIL SHEET AND NUMBER/LETTER.
  
 B) DELETE BBQ TO MATCH FLOOR PLAN.
  
 C) FOUNDATION NOTE #2. SEE CHAPTER 19
 FBC 2001 FOR PROPER CONCRETE REFERENCE.
 REVISE NOTE AS REQUIRED.
  
 2- SHEET A-3: A) STAIR WINDERS TO HAVE
 6" MIN. AT THE NARROWEST EDGE AS REQ'D
 BY SECTION 1007.8.1 FBC 2001. REVISE.
  
 B) KEYED DETAIL/SECTIONS DON'T MATCH.
 THERE IS NOT SHEET A-13. REVISE ALL
 DETAILS TO MATCH CORRECT SHEET & NUMBER.
  
 C) DESIGN PARAMETERS: WHERE IS THE BASIC
 VELOCITY PRESSURE TAKEN FROM?. THERE IS
 NOT MENTION OF THAT IN THE FBC 2001.
  
 3- SHEET A-7: A) REVISE THE TRUSS ANCHOR
 SCHEDULE. SEE LATEST CATALOGUE OR
 PROVIDE COMPLETE ENGINEERING CALCS FOR
 TYPE AND NUMBER OF FASTENERS THAT DIFFER
 FROM THOSE TESTED AND PUBLISHED BY THE
 MANUFACTURER. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 B) KEYED DETAILS/SECTIONS DON'T MATCH
 THOSE SHOWN ON DETAIL SHEET. REVISE AS
 REQUIRED.
  
 4- SHEET A-8: KEYED DETAILS DON'T MATCH
 THOSE SHOWN ON DETAIL SHEET. REVISE.
  
 5- SPECIFY ROOF TILE FASTENING AS REQ'D
 BY SEC. 104.2.1.1 CITY AMENDMENTS TO FBC
 2001.
  
 6- PLANS CALL FOR FLAT ROOF TILE.
 PRODUCT APPROVAL SUBMITTED IS FOR "S".
 TILE. REVISE PLANS AS REQUIRED.
  
 7- PROVIDE STRUCTURAL BUCK DETAIL FOR:
 A) WINDOWS. SEE SEC. 1707.4.4.2 FBC 2001
 B) DOORS. SEE SEC. 1707.4.4.2 FBC 2001
 FOR PROPER BUCK INSTALLATION.
 C) GARAGE DOOR.
  
 8- CLEARLY SPECIFY SIZE OF MULLION AND
 ANCHORS TO BE USED FOR DOOR MULLION
 ABOVE 12'-0" WIDE SLIDING GLASS DOORS.
 SEE PRODUCT APPROVAL AND VERIFY THAT
 MULLION WILL MEET THE REQUIRED DESIGN
 PRESSURES.
  
  
 9- CLARIFY IF USING THE STEEL DOORS FOR
 ENTRY DOORS. OTHERWISE, PROVIDE
 CORRESPONDING PRODUCT APPROVAL.
  
 10 ENERGY CALCULATIONS ARE INCOMPLETE:
 THIS IS A 2 STORY HOUSE AND CALCULATIONS
 WERE DONE WITHOUT INCLUDING THE 2ND
 FLOOR. REVISE AS REQUIRED.
  
 11- OWES $988.89 FOR UPDATED VALUATION
 AND RADON FEES.
  
 12- PROVIDE STAIRS COMPLETE STAIR
 FRAMING DETAILS AND SPECS.
 **PROVIDE HANDRAIL SPECS. SEE SECTION
 1007.5 FBC 2001.
 ***SPECIFY FIREBLOCKING. SEE SEC.
 2305.1.4 FBC 2001
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.