2005-04-22 00:00:00BUILDING REVIEW CHECKLIST:
 1- PAY IMPACT FEES. BRING BACK STAMPED
 DRAWINGS AND PAID RECEIPT.
  
 2- NEED RECORDED NOTICE OF COMMENCEMENT.
  
 3- SHEET A1: A) ATTIC ABOVE GARAGE USED
 FOR STORAGE NEEDS TO BE DESIGNED FOR
 30PSF LIVE LOAD AT BOTTOM CHORD OF
 TRUSS. REMAINDER OF ATTIC IF IS NOT USED
 FOR STORAGE NEEDS TO BE DESIGNED FOR
 10PSF AS REQUIRED BY TABLE 1604.1 FBC
 2001. REVISE NOTE ON GARAGE AREA AND
 CLEARLY INDICATE STORAGE OR NON STORAGE
 AREAS. SEE PLANS FOR COMMENTS.
  
 B) SPECIFY SAFETY GLASS AT FAMILY ROOM
 AND MASTER BEDROOM WINDOWS AS REQUIRED
 BY SEC. 2405.2.1(3) FBC 2001. SEE PLANS.
  
 C) SPECIFY SIZE OF ATTIC ACCESS IN
 MASTER BEDROOM CLOSET. SEC. 2309.6 FBC.
  
 D) REVISE ELEVATIONS FOR BEAMS AT ENTRY
 DOORS. SIZE OF DOOR IS TALLER THAN
 HEIGHT SPECIFIED FOR BEAM HEIGHT.
  
 E) SHOW ON PLAN PRIVACY WALL IN FRONT OF
 BATHROOM AS SHOWN ON FOUNDATION PLAN.
  
 4- SHEET A2: A)THERE ARE NOT FOOTINGS
 FOR PORTICO COLUMNS AND COLUMNS IN FRONT
 OF GARAGE. PROVIDE DETAILS SPECS AS
 REQ'D. SEC. 104.2.1.2 CITY AMENDMENTS TO
 FBC 2001.
  
 B) CLARIFY WHY FOOTINGS FOR CONCRETE
 BLOCK PIERS AT FRONT PRIVACY WALLARE
 BIGGER THAN THE FOOTINGS SPECIFIED FOR
 REAR PORCH AND INTERIOR STEEL COLUMN.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 5- SHEET A3: A) CLEARLY INDICATE ON ROOF
 FRAMING PLAN ANCHORS TO BE USED. SPECIFY
 ANCHORS AT ALL CONNECTIONS IN ROOF
 FRAMING PLAN. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 B) CONNECTOR SPECIFIED AT FRONT OF
 PORTICO IS FOR MASONRY APPLICATION.
 NEEDS WOOD TO WOOD CONNECTOR. REVISE AS
 REQ'D.
  
 C) REVISE ROOF LOADS CHART. NEED TO
 SPECIFY 30PSF AND 10PSF ATTIC LIVE LOAD
 IN THE ATTIC (BCLL) AS REQUIRED BY TABLE
 1604.1 FBC 2001.
  
 6- ELEVATIONS ON SHEET A6 DON'T MATCH
 FLOOR PLAN. RIGHT SIDE ELEVATION NEED TO
 SHOW POCKET FOR SLIDING GLASS DOORS AND
 MASTER BATHROOM GLASS BLOCK. REAR
 ELEVATION DON'T SHOW SAME TYPE AND
 NUMBER OF WINDOWS AS SPECIFIED ON PLANS.
  
  
 7- SHEET A7: REVISE CONNECTORS SPECIFIED
 ON WOOD BEARING WALL DETAIL. SEMCO IS
 OUT OF BUSINESS.
  
 8- PROVIDE FRAMING DETAILS AND SPECS FOR
 POCKET WALL AT SLIDING GLASS DOORS IN
 FAMILY ROOM. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 9- BBQ SPECS TYPICALLY SAY THAT THEY ARE
 DESIGNED FOR OUTDOORS ONLY. PROVIDE BBQ
 LISTING AND MANUFACTURER SPECS STATING
 THAT BBQ WILL BE OK TO INSTALL IN THE
 PORCH.SECTION 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 10- CLEARLY SPECIFY IF USING WINDOWS AND
 DOORS WITH IMPACT GLAZING OR SHUTTERS.
 BOTH PRODUCT APPROVALS WERE SUBMITTED
 AND IS NOT CLEAR WICH GLASS PROTECTION
 METHOD IS GOING TO BE INSTALLED.
  
 11- IF USING STORM SHUTTERS, THEN
 PROVIDE KEY PLAN AND COMPLETE
 INSTALLATION SCHEDULE. SEE SAMPLE. SEE
 SHUTTERS INSTALLATION SCHEDULE IN
 DRAWINGS AND MARK SPECIFIC ANCHOR AND
 SPACING TO BE USED.
  
 12- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR: A) 10'-0" H. ENTRY DOORS.
  
 B) 18'-0" WIDE GARAGE DOOR.
  
 C) POCKET SLIDING GLASS DOORS. SEE PLANS
  
 D) WINDOW MULLIONS.
  
 E) CASEMENT WINDOWS.\
  
 F) ALL TRUSS CONNECTORS SPECIFIED ON
 PLANS.
  
 G) HORIZONTAL SLIDER WINDOWS.
  
 H) BUTT GLAZING SYSTEM OR WINDOW
 ASSEMBLIES AS SHOWN ON MASTER BEDROOM,
 LIVING ROOM AND BREAKFAST AREA.
  
 I) FRENCH DOORS AS SHOWN ON PLANS.
  
 13- PROVIDE FRAMING DETAILS AND SPECS
 FOR CONSTRUCTION OF WALL ABOVE WINDOW IN
 BREAKFAST AREA. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 14- OWES $4247.67 FOR PERMIT FEES AND
 RADON FEES.
  
 15- ENERGY CALCULATIONS: A) THIS IS A
 MODEL HOUSE. NEED ENERGY CALCULATIONS
 FOR WORST CASE SCENARIO OR CALCULATIONS
 SHALL BE DONE WITH SPECIFIC HOUSE
 ORIENTATION IN LOT TO BE BUILT.
  
 B) OVERHANG LENGHT AND OVERHANG HEIGHT
 ARE INCORRECT. SEE PLANS AND ELEVATIONS
 AND REVISE ACCORDINGLY. SEE ATTACHED
 SKETCH SHOWING HOW OVERHANG LENGTH AND
 HEIGHT ARE CALCULATED.
  
 C) OWNER/AGENT TO SIGN AND DATE FORM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.