| Date |
Text |
| 2005-03-24 00:00:00 | |
| | DENIED |
| | |
| | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 2.PROJECT DESCRIPTION DOES NOT REFECT |
| | WORK ON PLANS. |
| | |
| | 3.PROJECT VALUATION OF $5600 IS TOO |
| | LOW.ADJUST VALUE TO REFLECT ALL WORK |
| | DONE ON PLANS.ADDITIONAL PERMIT FEES |
| | ARE DUE. |
| | IF VALUE IS NOT ADJUSTED CORRECTLY.I |
| | WILL ADJUST IT ACCORDING TO MARSHALL AND |
| | SWIFTS ESTIMATING GUIDE. |
| | |
| | 4.SUBMIT TWO COPIES OF PRODUCT |
| | APPROVALS WITH QUALITY ASSURANCE FOR THE |
| | FOLLOWING.EXTERIOR DOORS, WINDOWS, |
| | IMPACT PROTECTION AND STRAPS AND |
| | TIE-DOWNS. |
| | ALL PRODUCT APPROVALS REQUIRE THE |
| | FOLLOWING TO BE ATTACHED. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 5.SHOW CBS WALL REPAIR DETAIL. |
| | |
| | 6.CLEARLY SHOW ON PLANS EXISTING AREAS |
| | AND ALL NEW WORK. |
| | |
| | 7.WINDOW OVER TUB LOCATION WILL |
| | REQUIRE SAFTEY GLAZING ACCORDING TO |
| | FBC 2405.2.1 |
| | |
| | 8.SHOW INTERIOR BEARING WALL FRAMING |
| | DETAIL AND SHOW COMPLETE TIE DOWNS AND |
| | SUPPORT FROM FOOTINGS TO ROOF FRAMING. |
| | |
| | 9.SUBMIT A ROOF SHEATHING NAILING |
| | SCHEDULE SHOWING SHEATHING THICKNESS, |
| | FASTENERS AND SPACING.WEST PALM BEACH |
| | AMMENDMENTS TO THE FBC 2306.1 |
| | |
| | 10. SHOW SMOKE DETECTORS COMPLYING WITH |
| | FBC 905.2 |
| | |
| | 11.SHOW HOW ROOF VENTILATION WILL |
| | COMPLY WITH FBC 2309.7.2 |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |
| | |
| | |
| | |