2005-03-25 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) ALL DRAWINGS SHALL BEAR THE NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN. THIS IS FOR ALL SHEETS.
 SECTION 104.2.1.
 2) A WASH MACHINE HOOK-UP IS REQUIRED
 PER TABLE 403.1. PLEASE INDICATE THE
 LOCATION ON THE FLOOR PLAN OR INDICATE
 IF CENTRAL WASH FACILITIES ARE AVAILABLE
 3) PROVIDE LOCATION OF BAR SINK ON FLOOR
 PLAN. IF THIS IS A NEW FIXTURE PLEASE
 SUBMIT A SANITARY RISER DIAGRAM SHOWING
 THE PIPE SIZE, VENT, POINT OF CONNECTION
 AND A WATER RISER DIAGRAM SHOWING PIPE
 SIZE, VALVES, AND POINT OF CONNECTION.
 SECTION 104.3.1.1.
 4) IT APPEARS THAT THE KITCHEN SINK HAS
 CHANGED LOCATION. PLEASE INDICATE
 LOCATION OF ALL PLUMBING FIXTURES ON THE
 PLUMBING FLOOR PLAN. SECTION 104.2.1. IF
 THE KITCHEN SINK IS LOCATED IN A NEW
 LOCATION, SUBMIT A SANITARY RISER
 DIAGRAM AND A WATER RISER DIAGRAM
 SHOWING ALL REQUIRED INFORMATION AS
 REQUESTED IN COMMENT #3. SECTION
 104.3.1.1. - ALSO SHOW ALL REQUIRED
 WATER HAMMER ARRESTORS PER SECTION 604.9
 ON THE WATER RISER DIAGRAM.
  