| 2005-03-25 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 CHAPTER 1 |
| | |
| | 1) ALL DRAWINGS SHALL BEAR THE NAME AND |
| | SIGNATURE OF THE PERSON RESPONSIBLE FOR |
| | THE DESIGN. THIS IS FOR ALL SHEETS. |
| | SECTION 104.2.1. |
| | 2) A WASH MACHINE HOOK-UP IS REQUIRED |
| | PER TABLE 403.1. PLEASE INDICATE THE |
| | LOCATION ON THE FLOOR PLAN OR INDICATE |
| | IF CENTRAL WASH FACILITIES ARE AVAILABLE |
| | 3) PROVIDE LOCATION OF BAR SINK ON FLOOR |
| | PLAN. IF THIS IS A NEW FIXTURE PLEASE |
| | SUBMIT A SANITARY RISER DIAGRAM SHOWING |
| | THE PIPE SIZE, VENT, POINT OF CONNECTION |
| | AND A WATER RISER DIAGRAM SHOWING PIPE |
| | SIZE, VALVES, AND POINT OF CONNECTION. |
| | SECTION 104.3.1.1. |
| | 4) IT APPEARS THAT THE KITCHEN SINK HAS |
| | CHANGED LOCATION. PLEASE INDICATE |
| | LOCATION OF ALL PLUMBING FIXTURES ON THE |
| | PLUMBING FLOOR PLAN. SECTION 104.2.1. IF |
| | THE KITCHEN SINK IS LOCATED IN A NEW |
| | LOCATION, SUBMIT A SANITARY RISER |
| | DIAGRAM AND A WATER RISER DIAGRAM |
| | SHOWING ALL REQUIRED INFORMATION AS |
| | REQUESTED IN COMMENT #3. SECTION |
| | 104.3.1.1. - ALSO SHOW ALL REQUIRED |
| | WATER HAMMER ARRESTORS PER SECTION 604.9 |
| | ON THE WATER RISER DIAGRAM. |
| | |
| | REVIEW BY KEN STEVENS |