Plan Review Notes
Plan Review Notes For Permit 05030502
Permit Number 05030502
Review Stop P
Sequence Number 1
Notes
Date Text
2005-03-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) ALL ARCHITECTURAL SHEET AND PM&E
 PLANS, SECTION 104.2.1. ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME
 AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN.
 2) SHTS S1, S2, S3, SD1 & SD2 REQUIRE A
 CERTIFICATE OF AUTHORIZATION NUMBER IN
 THE TITLE BLOCK PER 61G15-23-002(2) AND
 FS 471.025. - ALSO THE DATE THAT THE
 SIGNATURE AND SEAL ARE AFFIXED TO THE
 PLANS SHALL BE ENTERED ON THE SEAL PER
 FAC 61G15-23.002(1) & FS 471.025.
 3) SHT P2 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE RQUIREMENTS.
 A) THE W/M IS NOT VENTED SEC 901.2.1.
 B) W/M CLEANOUT SHALL BE LOCATED 4' AFF
 FOR ACCESS. SECTION 708.10
 C) BIDET AND SHOWER ARE NOT VENTED IN
 THE MASTER BATH. SECTION 901.2.1.
 D) TUB NOT IDENTIFIED IN MASTER
 BATHROOM. SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]