| Plan Review Notes For Permit 05030459 |
| Permit Number |
05030459 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-03-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05030459 | | | ADD: 717 HOLLYWOOD PL | | | CONT:3-D HOMES | | | TEL: (561)718-7040 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: REVIEWED | | | | | | BUILDING PROVISOS: | | | | | | 1)NOA LIMITATIONS: SHALL NOT BE | | | INSTALLED ON ROOF MEAN HEIGHTS IN EXCESS | | | OF 33 FT. | | | | | | 2) 1507.3.8 ASPHALT SHINGLES ON LOW | | | SLOPED ROOFS, 2:12/ 4:12, (2) LAYERS OF | | | FELT W/ 19" LAP. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | 1507.3.8. ASPHALT SHINGLES LOW | | | SLOPE ROOFING, UNDERLAYMENT APPLICATION | | | FOR ROOF SLOPES FROM 2:12 UP TO 4:12, | | | UNDERLAYMENT SHAL BE A MINIMUM OF TWO | | | LAYERS APPLIED AS FOLLOWS: | | | 1) STARTING AT THE EAVE, A 19-INCH | | | STRIP OF UNDERLAYMENT SHALL BE APPLIED | | | PARALLEL WITH THE EAVE AND FASTENED | | | SUFFICIENTLY TO STAY IN PLACE. | | | 2) STARTING AT THE EAVE, 36-INCH-WIDE | | | STRIPS OF UNDERLAYMENT FELT SHALL BE | | | APPLIED OVER LAPPING SUCCESSIVE SHEETS | | | 19 INCHES AND FASTENED SUFFICIENTLY TO | | | STAY IN PLACE. | | | | | | N.O.A.-LIMITATIONS- SHALL NOT BE | | | INSTALLED ON ROOF MEAN HEIGHTS IN ACCESS | | | OF 33 FT. |
|