Plan Review Notes
Plan Review Notes For Permit 05030289
Permit Number 05030289
Review Stop P
Sequence Number 1
Notes
Date Text
2005-03-21 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SHT A-2 DETAIL A. THE FOLLOWING
 INFORMATION REQUIRED FOR THE ACCESSIBLE
 SINK IS NOT SHOWN ON THE DETAIL OR FLOOR
 PLAN:
 A) KNEE CLEARANCE 11-4.24.3
 B) SINK DEPTH 11-4.24.4
 C) CLEAR FLOOR SPACE 11-4.24.5 -
 FORWARD APPROACH REQUIRED, MAXIMUM 19"
 UNDERNEATH THE SINK. CABINET DOORS ARE
 NOT APPROVED PER THE BLDG. OFFICIAL, AS
 THEY SHALL NOT BE IN THE CLEAR FLOOR
 SPACE.
 D) FAUCETS 11-4.24.7
 2) A DRINKING FOUNTAIN IS REQUIRED.
 PLEASE INDICATE IF THERE ARE HI/LOW
 DRINKING FOUNTAINS EXISTING, AND THE
 LOCATION OF DRINKING FOUNTAINS. SECTION
 104.2.1.
 3) SHT P0.1 PLUMBING ISOMETRICS. WATER
 ISOMETRIC, WATER HAMMER ARRESTOR SHALL
 BE LOCATED NEAR THE FIXTURE, IN AN
 "EFFECTIVE RANGE" NOT IN THE CEILING AS
 SHOWN. PDI-WH 201. (SEE NOTE #13)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]