2005-03-07 00:00:00DENIED
  
 1) SUBMIT COMPLETE STATE PRODUCT
 APPROVAL WITH TEST REPORTS, LIMITATIONS
 AND INSTALLATION INSTRUCTIONS AND
 DRAWINGS FOR THE ASPHALT SHINGLES. MEAN
 ROOF HEIGHT IS LESS THAN 33 FEET,
 THEREFORE, MIAMI-DADE NOA IS ACCEPTABLE.
  
 2) ASTM C 926 REQUIRES PORTLAND CEMENT
 PLASTER TO BE 5/8" THICK WHEN APPLIED
 HORIZONTALLY OVER METAL PLASTER BASE.
 PLEASE REVISE THE SOFFIT DETAILS ON A-2.
  
 3) THE CITY OF WPB AMENDMENTS TO FBC
 TABLE 2306.1 REQUIRES THE ROOF SHEATHING
 TO BE NAILED AT 4" O.C. AT THE EDGES AND
 6"O.C. INTERMEDIATE IN ZONE 3, WHICH IS
 THE OUTSIDE CORNERS ON HIP ROOFS.
  
 4) THE UPLIFTS AND GRAVITY LOADS
 SPECIFIED ON S1 FOR TRUSSES S2 AND HGS
 ARE LESS THAN THOSE LISTED ON THE TRUSS
 DRAWINGS. PLEASE CORRECT.
  
 5) SUBMIT SITE PLANS INDICATING THE
 LOCATION OF THE STRUCTURE.
  
 6) FBC 11-4.2.6 REQUIRES THE SIDE REACH
 OF A PERSON IN A WHEEL CHAIR USING A
 PARALLEL APPROACH TO BE 54" FOR THE
 MAXIMUM HIGH SIDE REACH AND THE LOW SIDE
 REACH SHALL BE NO LESS THAN 9" ABOVE THE
 FLOOR. SHOW COMPLIANCE OF MAIL BOX
 UNITS.
  
 ROBERT MCDOUGAL