 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} SHOW THE LOCATION OF THE NEW SUB
 PANEL ON THE PLAN.
  
 2} IF EXISTING SERVICE AND SUBPANEL ARE
 ON THE SAME BUILDING WHY DOES THE
 SUBPANEL HAVE A GEC? COMPLY WITH 250.32.
  
 3} SHOW LIGHTING PER ARTICLE
 210.70(A)(1,2&3).
  
 4} SMOKE DETECTORS ARE REQUIRED PER
 8-1.4.1.6 NFPA-72.
  
 5} PER ARTICLE 3401.7.2.6 OF THE FLORIDA
 BUILDING CODE THE WIRING IN THE ENTIRE
 HOUSE, INCLUDING OUTSIDE RECEPTACLES,
 MUST BE MADE TO COMPLY WITH NFPA-70,
 2002, SHOW ON PLAN.
  