Notes
Date Text
2005-03-08 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) 713.13 F.S.SUBMITTAL OF A NOTICE OF
 COMMENCEMENT IS NOTED BUT IT MUST BE
 RE-RECORDED BECAUSE THE DESCRIBED
 IMPROVEMENT OR CONSTRUCTION DID NOT
 COMMENCE WITHIN 90 DAYS OF RECORDING.
  
 2) 61G1-16.004FL. ADMIN. CODE.EACH
 SHEET OF PLANS PREPARED BY A REGISTERED
 ARCHITECT SHALL INCLUDE A TITLE BLOCK
 WHICH MUST:
 - STATE THE FIRM LICENSE NUMBER (SEE
 COMMENT #3, BELOW)
 - INCLUDE THE PRINTED NAME OF THE
 ARCHITECT SEALING THE PLANS
 THIS INFORMATION MAY BE ADDED BY HAND.
  
 3) 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE
 THE CERTIFICATE OF AUTHORIZATION
 NUMBER.ADD THE NUMBER TO EACH SHEET.
 THIS MAY BE ADDED BY HAND.
  
 4) 61G15-23.002(2)FL. ADMIN. CODE.IT
 IS NOTED THAT THE STRUCTURAL PLAN SHEETS
 S-1 TO S-5 HAVE BEEN SIGNED AND SEALED
 BY ALBERT A GARGIULO, P.E. BUT HIS TITLE
 BLOCK DOES NOT APPEAR ON THOSE SHEETS.
 PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE EITHER THE NAME,
 ADDRESS AND LICENSE NUMBER OF THE
 ENGINEER OR, THE PRINTED NAME AND
 LICENSE NUMBER OF THE ENGINEER AND THE
 NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF ANY ENGINEERING
 BUSINESS THROUGH WHICH THE ENGINEER IS
 PRACTICING (471.025 F.S. AND 471.023
 F.S.).
  
 5) FBC 1804.4.2SHEET S-1, FOOTING
 SIZES.THE INCLUSION OF FOOTING TYPE
 MARKERS F-1, F-2 AND TE-1 ON THE PLAN IS
 NOTED.NO FOOTING SIZES SCHEDULE OR
 DESIGN SOIL BEARING CAPACITY STATEMENT
 ARE INCLUDED ON THE PLANS.ADD THE
 REQUIRED INFORMATION.
  
 6) FBC 1606.1SHEET S-4, TRUSS ANCHOR
 SCHEDULE. ANCHOR TYPE E, USP USC43 IS
 STATED AS HAVING AN UPLIFT CAPACITY OF
 12,340 LBS. THE 2005 USP CATALOGUE LISTS
 THE CAPACITY AS 11,150 LBS BECAUSE 1/3
 STRESS INCREASE IS NOT PERMITTED ON
 STEEL CAPACITIES.AMEND THE SCHEDULE
 AND ALSO THE ANCHOR FOR THE RIGHT SIDE
 VALLEY OVER THE FRONT ELEVATION WHICH IS
 SHOWN, ON SHEET S-3, AS HAVING A
 REQUIRED UPLIFT OF 11286 LBS
 (>11,150 LBS CAPACITY)
  
 7) SHEET S-4, STRUCTURAL NOTES, REFERS
 TO 'PALM BEACH COUNTY AMENDMENTS' UNDER
 THE SUBTITLE 'CODES'.AMEND THIS TO
 READ CITY OF WEST PALM BEACH AMENDMENTS.
  
 8) FBC 1604.1SHEET S-4, STRUCTURAL
 NOTES, 'GRAVITY LOAD' AND 'MATERIAL NOTE
 H - WOOD TRUSSES'.AMEND THE NOTES TO
 INCLUDE THE TRUSS BOTTOM CHORD LIVE LOAD
 REQUIREMENT OF 30 PSF FOR RESIDENTIAL
 ATTICS WITH STORAGE.
  
 9) FBC 3502SHEET S-4, STRUCTURAL
 NOTES, REFERS TO "ACI-95" (FOR
 REINFORCED CONCRETE) UNDER THE SUBTITLE
 'CODES'.THE STANDARD REFERENCED BY
 FLORIDA BUILDING CODE IS 'ACI 318-02 -
 BUILDING CODE REQUIREMENTS FOR
 STRUCTURAL CONCRETE'.AMEND THE NOTES.
  
 10) FBC 3502SHEET S-4, STRUCTURAL
 NOTES, REFERS TO OUTDATED STANDARDS ASTM
 C90-70, C140-70, C270-73 AND C150-74
 UNDER THE SUBTITLE 'CODES'.THE
 VERSIONS OF THESE STANDARDS REFERENCED
 BY FLORIDA BUILDING CODE ARE ASTM
 C90-99B, C140-99B, C270-00 AND C150-94.
 AMEND THE NOTES.
  
 11) FBC 11-11(1)SHEET A-12, POWDER
 ROOM DOOR 114.THE PROPOSED DOOR WIDTH
 IS 2'-6" WHICH WILL NOT GIVE THE
 REQUIRED CLEAR OPENING WIDTH OF 29" WHEN
 MEASURED IN ACCORDANCE WITH FIG. 24(A).
 AMEND THE DOOR SCHEDULE.
  
 12) FBC 2804.4SHEET A-10, FACTORY
 BUILT CHIMNEY/FIRE-BOX.SUBMIT TWO
 COPIES OF MANUFACTURER'S DATA COVERING
 INSTALLATION INSTRUCTIONS AND TEST
 REPORT LISTING.
  
 13) ONLY ONE COPY OF SOME DOCUMENTS HAVE
 BEEN SUBMITTED.TWO COPIES OF THE SITE
 SURVEY, SOIL REPORT AND ALL PRODUCT
 APPROVALS ARE REQUIRED.
  
 14) THE REQUIRED STATEWIDE PRODUCT
 APPROVAL LISTING COVER SHEETS HAVE BEEN
 ADDED TO THE SUBMITTED NOA'S FOR THE
 ROOF TILES AND GARAGE DOORS.PLEASE USE
 THESE AS EXAMPLES OF WHAT IS REQUIRED TO
 ADDRESS THE PRODUCT APPROVAL COMMENTS
 BELOW.
  
 15) SUBMIT PRODUCT APPROVALS FOR THE
 STANDING SEAM METAL ROOF AND THE
 MAHOGANY ENTRY DOOR (DOOR 101).
 NOTE: FL. ADMIN CODE RULE 9B-72 (IN
 EFFECT SINCE OCTOBER 1, 2003) REQUIRES
 THAT PRODUCTS HAVE STATEWIDE, LOCAL OR
 SITE-SPECIFIC PRODUCT APPROVAL.THE
 SUBMITTAL SHOULD INCLUDE THE STATEWIDE
 PRODUCT APPROVAL NUMBER (FL###),
 AVAILABLE FROM THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 (IF YOU FIND THAT THE QUOTED WEB PAGE IS
 NO LONGER AVAILABLE, PLEASE INFORM THE
 PLAN REVIEWER).
  
 16) FL. ADMIN CODE RULE 9B-72.
 A SEARCH AT THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 SHOWS NO MATCHING STATEWIDE PRODUCT
 APPROVAL FOR THE SUBMITTED CONSTRUCTION
 GLASS INDUSTRIES CORPORATION ALUMINUM
 STOREFRONT DOOR, FIXED WINDOW OR
 CASEMENT WINDOW PRODUCT APPROVAL NOA'S
 01-1109.03, 01-0918.01 AND 01-1002.03
 RESPECTIVELY.
 SPECIFY ALTERNATIVES THAT HAVE STATEWIDE
 OR LOCAL PRODUCT APPROVAL.IF YOU FIND
 THAT THE QUOTED WEB PAGE IS NO LONGER
 AVAILABLE, PLEASE INFORM THE PLAN
 REVIEWER.
  
 17) PRODUCT APPROVAL.RULE 9B-72 FAC.
 FOR PRODUCTS WHICH DO NOT HAVE STATEWIDE
 PRODUCT APPROVAL, LOCAL PRODUCT APPROVAL
 CAN BE ACHIEVED IF THERE IS A QUALITY
 ASSURANCE PROGRAM IN PLACE WITH A STATE
 APPROVED QUALITY ASSURANCE ENTITY.IF
 NEITHER IS APPLICABLE, THEN SITE
 SPECIFIC APPROVAL IS REQUIRED.LOCAL
 PRODUCT APPROVAL WILL ALLOW A PRODUCT TO
 BE USED, IN ACCORDANCE WITH THE TEST
 CRITERIA, THROUGHOUT THE JURISDICTION OF
 WEST PALM BEACH.SITE SPECIFIC PRODUCT
 APPROVAL WILL ALLOW A PRODUCT TO BE
 USED ONLY ON THE PROJECT FOR WHICH THAT
 SITE SPECIFIC APPROVAL IS GRANTED.
 LOCAL AND SITE SPECIFIC PRODUCT APPROVAL
 APPLICATION FORMS ARE AVAILABLE FROM
 THIS OFFICE.APPROVED QUALITY ASSURANCE
 ENTITIES ARE LISTED ON THE DCA WEBSITE:
 WWW.FLORIDABUILDING.ORG/COMMON/C_ORG_
 REGI_SRCH.ASP (IF YOU FIND THAT THE
 QUOTED WEB PAGE IS NO LONGER AVAILABLE,
 PLEASE INFORM THE PLAN REVIEWER)
  
 18) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS, TO FORM A SET OF
 'OLD/VOID SHEETS', FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]
  