2005-12-21 00:00:00********* UNSAT *********
  
 1)NOTE: PLEASE SEE THERE HAVE BEEN MAJOR
 CHANGES IN THE SCOPE OF ELECTRICAL WORK
 AND OTHER REMODEL WORK DONE FOR
 DWELLING.
 PLEASE SEE FBC ADMINSTRATIVE 104.6.5
 WHICH REQUIRES A MAJOR ADJUSTMENT IN
 VALUATION OF PERMITTING.
 PLEASE SEE ORIG WAS INCLUSIVE OF SOME
 REMODEL AND ADDITION WORK AT $130,000
 PLEASE ADJUST.
 PLANS ARE NOW INDICATING THE ENTIRE
 HOUSE BEING REWIRED.
  
 2)NOTE:PLEASE SEE SOME RECEPTS NOW
 MISSING DUE TO SOME WALL CHANGES.210.52
  
 3)NOTE: PLEASE BE SURE TO DOUBLE CHECK
 KITCHEN COUNTERSPACE AS SOME SPACING
 SEEMS TO REQUIRE ADDITIONAL
 RECEPTS.210.52C1
  
 4)NOTE: PLEASE SEE CU'S HAVE NOW BEEN
 MOVED TO SIDE OF DWELLING, HOWEVER A NEW
 GFI RECEPT WAS NOT ADDED FOR CU'S AS
 REQUIRED PER 210.63
  
 5)NOTE: PLEASE SEE SD IN MASTER BEDRM
 SHALL BE MOVED TO BE LOCATED WITHIN 3'
 OF THE PEAK OF THE SLOPED CEILING AS
 REQUIRED UNDER NFPA-72 11.8.3.5
 PLEASE SEE THIS WAS NOT NOTICED ON
 PREVIOUS REVIEW, HOWEVER STILL IS
 REQUIRED TO MEET CODE COMPLIANCE.
  
 6)NOTE: PLEASE SEE COMPLETE CHANGE IN
 ELECTRICAL SERVICE HAS NOW CREATED SOME
 ELECTRICAL COMMENTS:
  
 A)PLEASE SEE RISER DIAGRAM AS IT SHOWS A
 200A DISCONNECT FEEDING THE 200A PANEL
 WITH 3-#1'S ETC.
  
 B)PLEASE SEE CONDUCTORS TO POOL PANEL
 ARE NOW SHOWN AS 3/0'S??
 BOTH SEEM TO BE A MIX-UP OF SORTS,
 PLEASE CORRELATEAND ADJUST.
 310.16,240.4
  
 C)PLEASE SEE MISSING EQUIPMENT GROUNDING
 CONDUCTORS FROM METER/MAIN UP TO MAIN
 HOUSE. 250.32
 PLEASE ALSO SEE MISSING GROUNDING
 ELECTRODE SYSTEM AT MAIN HOUSE, SINCE
 SERVICE IS NOW MOVED.
  
 D)PLEASE SEE METER/MAIN IS SHOWN AS
 400A, AND THERE IS NO INDICATION OF THE
 OCP PROVIDED FOR SUB-PANEL FEEDERS TO
 MAIN HOUSE OR ANY OTHER BRANCH BRKRS.
 240.4,310.16 ETC.
 PLEASE ALSO VERIFY GUEST HOUSE BEING
 SHOWN WITH A MAIN DISCONNECT AND
 SUB-PANEL, AS IT IS SHOWN ON RISER BEING
 FED FROM THE METER MAIN PANEL AT GUEST
 HOUSE BLDG ALREADY?
 DISC?
  
 E)PLEASE ALSO VERIFY THE PANELS INSIDE
 THE MAIN HOUSE AS BOTH ARE SHOWN WITH
 MCB'S WHICH ARE PERMITTED ALTHOUGH NOT
 REQUIRED. THIS IS ONLY A NOTE AND NO
 CHNAGE IS NEEDED. PLEASE KNOW, IF SHOWN
 AS MCB , THEN THESE WILL BE REQUIRED.
  
 F)PLEASE SEE PANEL "C" AS THIS PANEL
 SCHEDULE SHOWS THE OCP AND FEED FOR
 GUEST HOUSE PANEL.??
 PLEASE CORRELATE WITH THE ABOVE NOTES
 AND PLANS.
  
 7)NOTE: PLEASE INDICATE THE GFI
 PROTECTION REQUIRED FOR SPA/JACUZZI AT
 MASTER BATH. THIS WAS REDLINED ON
 PREVIOUS PLANS.
 680.71
  
 8)NOTE: PLEASE SEE WHAT APPEARS TO BE
 SWITCHED RECEPTS IN A ROOM WITHOUT ANY
 MEANS OF CONTROL.
  
 9)NOTE: PLEASE PROVIDE ALL ROOM AND AREA
 DESIGNATIONS ON PLANS.
  
 10)NOTE: PLEASE SEE BLDG AND ZONING
 COMMENTS AS BLDG ELECTRICAL AND ZONING
 CHANGES ON SITE PLANS, AND DETAILED SITE
 PLAN WILL BE REQUIRED TO BE DONE UNDER
 SEPARATE PERMITS FOR FENCE/GATES,
 FOUNTAIN, ETC. SEE OTHER REVIEWERS
 NOTES.
 ELECTRIC FOR GATES , LTS ETC SHALL BE ON
 SEPARATE PLANS AND PERMITS. PLEASE KNOW,
 WHEN SUBMITTING FOR ELECTRICAL FOR
 GATES, SUPPLY ANY GATE CONTOLLER
 SPEC/CUT SHEETS AND BE SURE THEY CONTAIN
 A LISTING FROM A NRTL.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  