Plan Review Notes
Plan Review Notes For Permit 05020016
Permit Number 05020016
Review Stop Z
Sequence Number 1
Notes
Date Text
2005-02-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05020016
 ADD: 1382 9TH CT.
 CONT:O/B RICE, EVELYN
 TEL: (561)655-9774
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: REVIEWED
  
 PROVISO:
  
 1) 2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.