Plan Review Notes
Plan Review Notes For Permit 05020016
Permit Number 05020016
Review Stop B
Sequence Number 1
Notes
Date Text
2005-02-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05020016
 ADD: 1382 9TH CT
 CONT:O/B RICE, EVELYN
 TEL: (561)655-9774
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: REVIEWED/ PROVISO
  
  
 1)2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL
 HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
  
 2)3401.7.2.4 FOR ONE & TWO FAMILY
 DWELLINGS CONSTRUCTED UNDER CODES OTHER
 THAN THE FLORIDA BUILDING CODE AND
 LOCATED IN WINDBORNE DEBRIS REGIONS, THE
 REPLACEMENT OF GARAGE DOORS AND EXTERIOR
 DOORS WITH GLAZING, SLIDING GLASS
 DOORS,
 GLASS PATIO DOORS, SKYLIGHTS, AND
 OPERABLE AND INOPERABLE WINDOWS WITHIN
 ANY 12 MONTH PERIOD SHALL NOT REQUIRE
 PROTECTION, BUT SHALL BE DESIGNED FOR
 WIND PRESSURES FOR ENCLOSED BUILDINGS
 PROVIDED THE AGGREGATE AREA OF THE
 GLAZING IN THE REPLACED COMPONENTS DOES
 NOT EXCEED 25% OF THE AGGREGATE AREA OF
 THE GLAZED OPENINGS IN THE DWELLING OR
 DWELLING UNIT.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026