| Plan Review Notes For Permit 05011469 |
| Permit Number |
05011469 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-04-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A-5 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. CORRECT THE | | | FOLLOWING: | | | A) NO TRAP FOR THE WATER CLOSET AS IT | | | HAS AN INTEGRAL TRAP. SECTION 1002.1 | | | B) SHOW THE TRAP AND STANDPIPE ON THE | | | WASH MACHINE SECTIONS 901.2.1 & 1002.1. | | | C) WASH MACHINE SHALL NOT DISCHARGE | | | INTO THE WET-VENTED BATHROOM GROUP. | | | SECTION 909.1 | | | D) LAV ON SEPARATE WALL FROM W/M | | | SECTION 104.2.1. | | | E) 2ND FLOOR BATHROOMS DO NOT REFLECT | | | THE FLOOR PLAN. SECTION 104.2.1. | | | 2) SEE ATTACHED SHEET SHOWING AN EXAMPLE | | | OF A SANT. RISER DIAGRAM THAT MEETS THE | | | CODE REQUIREMENTS AND REFLECTS THE FLOOR | | | PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|