Plan Review Notes
Plan Review Notes For Permit 05011402
Permit Number 05011402
Review Stop B
Sequence Number 1
Notes
Date Text
2005-02-09 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05011402
 ADD: 1256 PALM BEACH LAKES BLVD
 CONT:MASTER CONTRACTOR, INC.
 TEL: (561)712-8898
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION:DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE
 SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 ARCHITECTS:61G1-16.004 & FSS 481.219
 WITHIN THE TITLE BLOCK PROVIDE THE
 FIRMS
 LICENSE (CERTIFICATE OF AUTHORIZATION)
 THIS COMMENT HAS BEEN REQUESTED ON
 PREVIOUS PROJECTS FROM THE SAME FIRM.
  
 3) PLANS HAVE BEEN ALTERED BY PEN &
 WHITE OUT: 104.2.1.3 THE BUILDING
 OFFICIAL MAY SET STANDARDS THROUGH
 DEPARTMENTAL POLICY STANDARDS FOR PLANS
 AND SPRCIFICA TIONS. "NO WHITE OUT".
  
 4) PLANS INDICATETHAT A 6'-0"X7'-0"
 OPENING TO RECEIVE NEW JAMBS AND DOORS,
 BUT NO PRODUCT APPROVAL WAS SUBMITTED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5A) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 PLANS INDICATE A NEW FRONT FACADE TO BE
  
 BUILT IN STEEL, NO INFORMATION WAS
 PROVIDED AS TO THE GAUGE OF STEEL USED,
 SPACING, NOR THE ATTACHMENT OF THE
 STEEL
 TRUSS TO THE EXISTING STRUCTURE. WHAT
 ARE THE LOADS IMPOSED?
 5B) THE NEW FACADE INDICATES USE OF
 CEMENT BOARD, PROVIDE THICKNESS OF THE
 PRODUCT.
  
 6) PLAN HEADER INDICATES THAT THIS
 STRUCTURE HAS FIRE DAMAGE, LETTER FROM
 ENGINEER TO CERTIFY NO DAMAGE TO
 STRUCTURAL COMPONENTS, INCLUDING,
 STRUCTURAL WALLS, COLUMNS, BAR JOIST AND
 THE ROOF DECK.
  
 7) HEADER ALSO INDICATES NEW WINDOWS IN
 THE RESTROOMS, NO PRODUCT APPROVALS
 WERE
 SUBMITTED.
  
 8) PERMIT APPLICATION INDICATES REPAIRS
 AS TO PLANS, BUT NO OCCUPANCY
 CLASSIFICATION WAS PROVIDED, NOR DETAILS
 TO FINISH THE INTERIOR? IS THIS FOR THE
 SHELL ONLY?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved