| Date |
Text |
| 2005-01-18 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 805 6716 |
| | E-MAIL: [email protected] |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | F.S.= FLORIDA (STATE) STATUTE |
| | |
| | |
| | 1) FBC* 104.4.5 BEFORE A SPECIAL |
| | FOUNDATION PERMIT CAN BE ISSUED, THE |
| | PERMIT TO CONSTRUCT THE BUILDING MUST |
| | BE |
| | FILED. CURRENTLY, THE STATUS OF THE |
| | BUILDING PLANS IS 'SUBMITTED FOR MAJOR |
| | WORKING DRAWING REVIEW ONLY'.THE |
| | PERMIT APPLICATION HAS NOT YET BEEN |
| | FILED. |
| | |
| | 2) FBC* 104.4.5 THE HOLDER OF A SPECIAL |
| | FOUNDATION PERMIT IS PROCEEDING AT |
| | HIS/HER OWN RISK AND WITHOUT ASSURANCE |
| | THAT A PERMIT FOR THE REMAINDER OF THE |
| | WORK WILL BE GRANTED AND THAT |
| | CORRECTIONS WILL NOT BE REQUIRED IN |
| | ORDER TO MEET THE PROVISIONS OF THE |
| | TECHNICAL CODES. |
| | |
| | 3) 713.13 F.S.A NOTICE OF |
| | COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST |
| | BE |
| | RE-RECORDED IF THE DESCRIBED |
| | IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 4) IMPACT FEES. ARCHITECTURAL PLANS (3 |
| | COPIES, MINIMUM) WITH BUILDING AREA |
| | CALCULATIONS SHALL BE TAKEN TO PALM |
| | BEACH COUNTY BUILDING DEPARTMENT FOR |
| | IMPACT FEE ASSESSMENT. THEY SHALL BE |
| | STAMPED AT THAT OFFICE AND A COPY OF |
| | THE |
| | PAID RECEIPT SUBMITTED TO THE CITY OF |
| | WEST PALM BEACH DEPT OF CONSTRUCTION |
| | SERVICES BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 5) FBC* 105.13.1SPECIAL INSPECTOR.A |
| | STRUCTURAL INSPECTION PLAN MUST BE |
| | SUBMITTED PRIOR TO THE ISSUANCE OF A |
| | BUILDING PERMIT FOR THE CONSTRUCTION OF |
| | A THRESHOLD BUILDING.A THRESHOLD |
| | BUILDING IS ANY BUILDING WHICH IS |
| | GREATER THAN THREE STORIES OR 50 FEET |
| | IN |
| | HEIGHT, OR WHICH HAS AN ASSEMBLY |
| | OCCUPANCY WITH 5,000 SQFT AREA AND |
| | GREATER THAN 500 OCCUPANTS.THREE |
| | COPIES OF THE PLANS AND OTHER DOCUMENTS |
| | WILL BE REQUIRED FOR PERMITTING |
| | PURPOSES |
| | ALSO, PLEASE ARRANGE WITH HAROLD |
| | PISKURA |
| | (INSPECTION SERVICES MANAGER - TEL: |
| | 561 805 6711), A MEETING INVOLVING THE |
| | OWNER, THRESHOLD INSPECTOR, JOB |
| | INSPECTOR, CONTRACTOR AND ENGINEER. |
| | |
| | 6) FBC* 104.2.4SITE SURVEY.THREE |
| | SIGNED AND SEALED COPIES OF A SURVEY |
| | DRAWING PREPARED BY A LICENSED |
| | SURVEYOR/MAPPER ARE REQUIRED. (REF: |
| | 472.025(1) FL. STATUTES) |
| | |
| | 7) FBC* 1804.2.2SHEET S-0.0, GENERAL |
| | NOTES, FOUNDATIONS.SUBMIT THREE |
| | COPIES |
| | OF THE ARDAMAN & ASSOCIATES |
| | GEOTECHNICAL |
| | REPORT# 04-2096 (DATED JULY 26, 2004) |
| | AS |
| | REFERENCED UNDER THE 'FOUNDATIONS' |
| | NOTE. |
| | |
| | 8) FBC* 1606.1.1SHEET S-0.0, GENERAL |
| | NOTES, WIND LOADS.SUBMIT THREE COPIES |
| | OF THE RWDI WIND TUNNEL TEST REPORT# |
| | 04-1598 AS REFERENCED UNDER THE 'WIND |
| | LOADS' NOTE. |
| | |
| | 9) FBC* 104.2.1THE FOUNDATION PERMIT |
| | APPLICATION SHALL INCLUDE THE |
| | FOUNDATION |
| | DETAILS SHOWN ON SHEETS S-0.2, S-0.3, |
| | S-0.4, S-5.0 AND S-5.1.ADD THESE |
| | SHEETS TO EACH SUBMITTED PLAN SET. |
| | |
| | 10) FBC* 104.2.1THE FOUNDATION PERMIT |
| | APPLICATION SHALL INCLUDE THE COLUMN |
| | SCHEDULES SHOWN ON SHEETS S-4.0 AND |
| | S-4.1.ADD THESE SHEETS TO EACH |
| | SUBMITTED PLAN SET. |
| | |
| | 11) SEE PROVISO UNDER ZONING PLAN |
| | REVIEW. |
| | |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL |
| | INFO |
| | TELEPHONE: (561) 805 6716ROBERT |
| | BROWN |
| | E-MAIL: [email protected] |