| 2005-01-18 00:00:00 | DENIED |
| | |
| | 1.PRODUCT APPROVALS: |
| | SUBMIT TWO COPIES OF PRODUCT APPROVALS |
| | FOR STRAPS AND TIE-DOWNS, IMPACT |
| | PROTECTION AND HARDIE BOARD SIDING AND |
| | ROOFING. |
| | |
| | PRODUCT APPROVAL FOR FRENCH DOOR IS FOR |
| | AN OUT SWING DOOR.PLANS SHOW AN |
| | INSWING DOOR.PLEASE VERIFY. |
| | |
| | ALL PRODUCT APPROVALS REQUIRE THE |
| | FOLLOWING TO BE ATTACHED. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 2.NEW DOOR TO BE IMPACT RESISTANT OR |
| | HAVE IMPACT PROTECTION. |
| | |
| | 3.PLEASE SHOW SPACING OF 1/2 X 5" |
| | LAG SCREWS ON LEDGER.ALSO VERIFY |
| | CORRECT LENGTH. 3" OF 2X MATERIAL PLUS |
| | STUCCO ONLY LEAVES APPROX. 1" OF |
| | EMBEDMENT. |
| | |
| | 4.1015.2 HEIGHT. GUARDRAILS SHALL |
| | FORM A VERTICAL PROTECTIVE BARRIER NOT |
| | LESS THAN 42" HIGH. |
| | 1015.3 OPENINGS. OPEN GUARDRAILS |
| | SHALL HAVE INTERMEDIATE RAILS OR ORNA- |
| | MENTAL PATTERNS SUCH AS A 4" DIAMETER |
| | SPHERE CAN NOT PASS THROUGH. A BOTTOM |
| | RAIL OR CURB SHALL BE PROVIDED THAT |
| | WILL |
| | REJECT THE PASSAGE OF 2" DIAMETER |
| | SPHERE. |
| | PLEASE SHOW DETAIL ON PLANS. |
| | |
| | 5.SHOW A DETAIL FOR SPIRAL STAIRCASE. |
| | INCLUDE THE FOLLOWING, RISE, RUN, TREAD |
| | DEPTH, HAINDRAILS AND TURN IF |
| | STAIRCASE. |
| | FBC 1007.8.2.1 |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT |
| | NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE |
| | FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |