| 2005-02-22 00:00:00 | DENIED |
| | |
| | 1) FBC 11-4.23.2 REQUIRES AT LEAST ONE |
| | FULL BATHROOM WITH A DOOR THAT HAS A 29" |
| | CLEAR OPENING. THE 2-6 DOOR ON THE PLAN |
| | WILL NOT PROVIDE THE REQUIRED CLEAR |
| | OPENING WIDTH WHICH IS MEASURED BETWEEN |
| | THE FACE OF THE DOOR AND THE OPPOSITE |
| | STOP, WITH THE DOOR OPEN 90 DEGREES. |
| | |
| | 2) SPECIFY THE POSITIVE AND NEGATIVE |
| | WINDLOAD PRESSURES FOR THE SMALL GOLF |
| | CART GARAGE DOOR. |
| | |
| | 3) SUBMIT THE STATE/LOCAL PRODUCT |
| | APPROVAL FOR THE SINGLE OUTSWING GLAZED |
| | DOOR. THE ONE SUBMITTED IS FOR DOUBLE |
| | OUTSWING DOORS. |
| | |
| | 4) SUBMIT THE STATE/LOCAL PRODUCT |
| | APPROVAL FOR THE DOUBLE OUTSWING GLAZED |
| | WOOD FRONT DOORS AS SPECIFIED ON THE |
| | PLANS. THESE DOORS ARE NOT SHOWN ON THE |
| | STORM PANEL SCHEDULE AS BEING SHUTTERED. |
| | THEREFORE, THE PRODUCT APPROVAL FOR |
| | IMPACT RESISTANT DOORS IS REQUIRED. IF |
| | THE DOORS ARE NOT WOOD, THEY SHOULD NOT |
| | BE SPECIFIED AS SUCH ON SHEET A3. |
| | |
| | 5)FBC 1005.4.5 (GLITCH AMENDMENTS |
| | JULY 1, 2003) REQUIRES AT LEAST ONE |
| | MEANS OF ESCAPE FROM A DWELLING WHEN |
| | SHUTTERED FOR IMPACT PROTECTION. THE |
| | MEANS OF ESCAPE SHALL BE WITHIN THE |
| | FIRST FLOOR OF THE DWELLING AND CAN NOT |
| | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY |
| | PART OF THE DWELLING SHALL HAVE ACCESS |
| | TO IT WITHOUT HAVING TO PASS THROUGH A |
| | LOCKABLE DOOR NOT UNDER THEIR CONTROL. |
| | INDICATE HOW COMPLIANCE WILL BE |
| | ACHIEVED. |
| | |