2005-02-22 00:00:00DENIED
  
 1) FBC 11-4.23.2 REQUIRES AT LEAST ONE
 FULL BATHROOM WITH A DOOR THAT HAS A 29"
 CLEAR OPENING. THE 2-6 DOOR ON THE PLAN
 WILL NOT PROVIDE THE REQUIRED CLEAR
 OPENING WIDTH WHICH IS MEASURED BETWEEN
 THE FACE OF THE DOOR AND THE OPPOSITE
 STOP, WITH THE DOOR OPEN 90 DEGREES.
  
 2) SPECIFY THE POSITIVE AND NEGATIVE
 WINDLOAD PRESSURES FOR THE SMALL GOLF
 CART GARAGE DOOR.
  
 3) SUBMIT THE STATE/LOCAL PRODUCT
 APPROVAL FOR THE SINGLE OUTSWING GLAZED
 DOOR. THE ONE SUBMITTED IS FOR DOUBLE
 OUTSWING DOORS.
  
 4) SUBMIT THE STATE/LOCAL PRODUCT
 APPROVAL FOR THE DOUBLE OUTSWING GLAZED
 WOOD FRONT DOORS AS SPECIFIED ON THE
 PLANS. THESE DOORS ARE NOT SHOWN ON THE
 STORM PANEL SCHEDULE AS BEING SHUTTERED.
 THEREFORE, THE PRODUCT APPROVAL FOR
 IMPACT RESISTANT DOORS IS REQUIRED. IF
 THE DOORS ARE NOT WOOD, THEY SHOULD NOT
 BE SPECIFIED AS SUCH ON SHEET A3.
  
 5)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  