| Date |
Text |
| 2005-09-27 00:00:00 | DENIED BY BUILDING |
| | |
| | REVISIONS TO STORM PANELS ARE DENIED. |
| | |
| | 1) PRODUCT APPROVALS SUBMITTED |
| | WITH PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE |
| | AT WWW.FLORIDABUILDING.ORG. PRODUCTS |
| | WITH STATEWIDE APPROVAL ARE REQUIRED TO |
| | BE SUBMITTED WITH A COVER SHEET THAT |
| | LISTS THE PRODUCT IDENTITY NUMBER FROM |
| | THE STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. |
| | |
| | 2) THE DESIGN LOAD TABLES ARE FOR |
| | EXPOSURE C AND A MAXIMUM 2:12 ROOF |
| | PITCH. THE STRUCTURE IS EXPOSURE B WITH |
| | A 5:12 PITCH ROOF. SHOW HOW THIS TABLE |
| | WAS USED TO DETERMINE THE PRESSURES |
| | LISTED IN YOUR INSTALLATION SCHEDULE. |
| | |
| | 3) THE MEAN ROOF HEIGHT OF THE STRUCTURE |
| | IS 23'-9" AS SPECIFIED ON THE BUILDING |
| | PLANS, NOT 26.5'. |
| | |
| | 4) THE END ZONE FOR THIS STRUCTURE IS |
| | 5.7' WIDE. SOME OF THE OPENINGS ARE |
| | LOCATED WITHIN THE END ZONE, BUT NONE |
| | ARE LISTED ON THE INSTALLATION SCHEDULE. |
| | |
| | 5) SPECIFY THE EDGE DISTANCE ON |
| | INSTALLATION SCHEDULE. |
| | |
| | 6) SPECIFY THE FASTENERS ON THE SCHEDULE |
| | FOR EACH OPENING. SOME OF THE SPACINGS |
| | THAT ARE HI-LITED ON THE PRODUCT |
| | APPROVAL DIFFER FROM THE 16" SPACING |
| | THAT IS LISTED FOR EVERY OPENING ON THE |
| | INSTALLATION SCHEDULE BASED ON SPAN, |
| | EDGE DISTANCE, CONNECTION TYPE, ANCHOR |
| | TYPE AND SUBSTRATE TYPE. |
| | |
| | 7) OPENING 1 ON THE KEY PLAN SHOULD BE |
| | ABOVE THE FRONT DOOR. |
| | |
| | 8) PROVIDE THE OPENING DIMENSIONS ON THE |
| | KEY PLAN. THE # OF PANELS IS NOT |
| | NECESSARY AND STEEL GAUGE IS IN THE |
| | PRODUCT APPROVAL. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |