| Plan Review Notes For Permit 04121902 |
| Permit Number |
04121902 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-05-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT A-9 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. CORRECT THE | | | FOLLOWING: | | | A. CLEANOUT FOR THE WASH MACHINE SHALL | | | BE LOCATED 4' ABOVE THE FLOOR. SECTION | | | 708.10. | | | B. THE CABANA BATH IS NOT SHOWN ON THE | | | RISER DIAGRAM. SECTION 104.2.1. | | | C. THE FUTURE SINK PIPING IS UNCLEAR. | | | PLEASE INDICATE IF IT WILL BE LEFT UNDER | | | THE SLAB. IF NOT SHOW THE RISER AND | | | INDICATE METHOD OF VENT. SECTIONS | | | 104.2.1. & 901.2.1. | | | D. THE FITTING AT THE TOP OF THE RISER | | | TO THE SECOND FLOOR DOES NOT DIRECT THE | | | WASTE IN THE DIRECTION OF FLOW AS | | | REQUIRED IN SECTION 706.3. SEE RED LINE | | | EXAMPLE AT TOP OF RISER ONE SET OF | | | PLANS. | | | 2. LOOSE SHEETS ARE NOT ACCEPTABLE. | | | PLEASE SUBMIT 2 SETS OF PLANS PER | | | SECTIONS 104.2.1, AND 104.2.1.3. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|