| 2005-01-24 00:00:00 | DENIED |
| | |
| | 1) ONE OF THE WINDOWS IN BEDROOM #3 |
| | SPECIFIED AS AN EGRESS WINDOW IS LABELED |
| | H33 SH, WHICH DOES NOT MEET EGRESS |
| | REQUIREMENTS OF FBC 1005.4. |
| | |
| | 2) SUBMIT THE MANUFACTURER'S SPECS. AND |
| | LISTING INFORMATIONFOR TH BBQ AND PREFAB |
| | FIREPLACE. |
| | |
| | 3) FBC 1007.8.1 REQUIRES STAIR WINDERS |
| | TO HAVE A MINIMUM TREAD DEPTH OF 6 |
| | INCHES AT THE NARROW EDGE AND SHALL HAVE |
| | A MINIMUM TREAD DEPTH OF 11 INCHES AT A |
| | POINT 12 INCHES FROM THE NARROW EDGE. |
| | |
| | 4) PROVIDE DETAILS OF THE HANDRAILS AND |
| | GUARD RAILS AT THE STAIRS. SEE FBC |
| | 1007.5 AND 1015. |
| | |
| | 5) SPECIFY THE WINDLOAD PRESSURES FOR |
| | THE 7' X 5' FIXED GLASS WINDOW AT THE |
| | BREAKFAST NOOK. |
| | |
| | 6) SPECIFY THE LENGTH/EMBED DEPTH OF THE |
| | ANCHOR BOLTS ON DETAIL 6 ON A7. |
| | |
| | 7) THE DETAIL FOR THE WOOD FRAME WALL ON |
| | A8 SPECIFIES A USP RT16F AT THE BOTTOM |
| | OF THE WALL AND DETAIL 7 ON A12 |
| | SPECIFIES A USP RT18F AT THE SAME |
| | LOCATION. PLEASE CLARIFY. |
| | |
| | 8) THE GLASS BLOCK DETAIL ON A12 |
| | INCORRECTLY REFERENCES ASCE 7-88. THE |
| | CORRECT REFERENCE IS ASCE 7-98. |
| | |
| | 9) SECTIONS 1 AND 2 ON A 13 SPECIFY FIRE |
| | STOPS AT 8 INCHES ON CENTER. PLEASE |
| | CORRECT. |
| | |
| | 10) THE OWNER/AGENT IS REQUIRED TO SIGN |
| | THE ENERGY CALC. FORMS PER FBC CHAPTER |
| | 13. |
| | |
| | 11) SUBMIT TWO COPIES OF A KEY PLAN FOR |
| | THE STORM PANELS. |
| | |
| | 12) SUBMIT STATE/LOCAL PRODUCT APPROVALS |
| | FOR THE DOUBLE OUTSWING WOOD GLAZED |
| | DOORS AT THE ENTRY AND THE SINGLE |
| | OUTSWING GLAZED DOOR AT THE MASTER |
| | BEDROOM. |
| | |
| | 13)FBC 1005.4.5 (GLITCH AMENDMENTS |
| | JULY 1, 2003) REQUIRES AT LEAST ONE |
| | MEANS OF ESCAPE FROM A DWELLING WHEN |
| | SHUTTERED FOR IMPACT PROTECTION. THE |
| | MEANS OF ESCAPE SHALL BE WITHIN THE |
| | FIRST FLOOR OF THE DWELLING AND CAN NOT |
| | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY |
| | PART OF THE DWELLING SHALL HAVE ACCESS |
| | TO IT WITHOUT HAVING TO PASS THROUGH A |
| | LOCKABLE DOOR NOT UNDER THEIR CONTROL. |
| | INDICATE HOW COMPLIANCE WILL BE |
| | ACHIEVED. |
| | |
| | 14) THE PRODUCT APPROVAL SUBMITTED FOR |
| | THE MULLIONS DO NOT MEET THE REQUIRED |
| | PRESSURES FOR USE BETWEEN THE 12' |
| | SLIDING GLASS DOOR AND THE TRANSOM AT |
| | THE FAMILY ROOM. |
| | |