| 2005-03-29 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: |
| | PROVIDE THE FOLLOWING INFORMATION PRIOR |
| | TO INSTALLATION OR CONSTRUCTION TO AVOID |
| | CONFLICTS OR DELAYS. |
| | 1- DESIGNER OF RECORD TO SPECIFY ROOF |
| | TILE FASTENING AS REQUIRED BY SECTION |
| | 104.2.1..1 CITY AMENDMENTS TO FBC. |
| | |
| | 2- UPDATE TRUSS ANCHOR SCHEDULE. SEE |
| | LATEST CATALOGUE. PROVIDE COMPLETE |
| | ENGINEERING CALCULATIONS THAT COMPLY |
| | WITH SEC. 1609.4.3 FBC 2001 IF TYPE AND |
| | NUMBER OF FASTENERS DIFFER FROM THOSE |
| | TESTED AND PUBLISHED BY MANUFACTURER. |
| | |
| | 3- PROVIDE FLORIDA OR LOCAL PRODUCT |
| | APPROVAL FOR: A) FRENCH DOORS WITH |
| | SIDELITES AS SHOWN ON PLANS. |
| | B)"OUTSWING" FRENCH DOORS AS SHOWN ON |
| | PLANS. PRODUCT APPROVAL SUBMITTED IS FOR |
| | "INSWING" FRENCH DOORS. |
| | C) USP OR SIMPSON TRUSS CONNECTORS USED. |
| | |
| | 4- PROVIDE COMPLETE & CORRECT INFO. FOR |
| | STORM SHUTTERS UNDER A SEPARATE PERMIT. |
| | CHECK SIZE AND NUMBER OF OPENINGS WITH |
| | PLANS AND CLEARLY INDICATE ON SHUTTER |
| | DWGS SPECIFIC MOUNTING CONDITIONS AND |
| | ANCHOR TYPE AND SPACING TO BE USED. |
| | |
| | 5- PLANS CALL FOR FLAT CEMENT TILE. |
| | PRODUCT APPROVAL SUBMITTED WAS FOR "S" |
| | TILE. CLARIFY/REVISE AS REQUIRED. |