Plan Review Notes
Plan Review Notes For Permit 04121835
Permit Number 04121835
Review Stop E
Sequence Number 2
Notes
Date Text
2005-05-09 00:00:00************** UNSAT *************
  
 PLEASE SEE SAME COMMENTS AS PREVIOUS
 REVIEW.
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH A PANEL
 SCHEDULE(S) TO BE SUBMITTED.
 215.5
 PLEASE SEE ALL MIN REQUIRED PER2002
 NEC.
  
  
 2)NOTE: PLEASE SEE 110.26 FOR CLEARENCE
 REQUIRED FOR PANEL. APPEARS TO BE SHOWN
 ABOVE KITCHEN COUNTERSPACE.
 THIS APPEARS TO RELOCATED FROM PREVIOUS
 REVIEW.
  
 3)NOTE: PLEASE SHOW ANY EXISTING
 ELECTRICALTO MEET 2002 NEC. PLANS
 APPEAR TO SOME NEW ELECTRICAL BUT NOT
 CLEAR OF ALL IS TO BE NEW OR EXSITING?
 PLEASE SHOW ALL MIN REQUIRED UNDER 2002
 NEC.
 PLEASE SEE 210.52,210.8,210.11 ETC
 PLEASE SEE 2002 NECIF ALL SHOWN IS
 NEW, PLEASE SEE THERE ARE NUMEROUS ITMES
 FOR NEC CODE COMPIANCE MISSING.
 PLEASE ALSO SEE FBC CHAPTER 34 FOR
 REMODEL WORK.3401.7.2
  
 4)NOTE: PLEASE SEE "LITE TOUCH" SYSTEM
 IS NOW BEING SHOWN FOR INSTALLATION.
 PLEASE PROVIDE MANUFACTURE SPEC/CUT
 SHEETS FOR THIS SHOWING THE NRTL
 LISTING.
  
 5)NOTE: PLEASE SEE SEE COPY OF FS
 553.80(2)(B) ATTACHED WITH RESPECT TO
 DESIGN PROFESSIONAL. THIS IS A NOTICE
 ONLY GIVEN AT THIS TIME.
  
 PLEASE BE SURE TO REMOVE ALL OLD/ VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO COMPLETE SETS FOR REVIEW AND
 STMAPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  