2005-01-21 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04121835
 ADD: 525 S FLAGLER DR 2901/2902
 CONT: DESIGN CONTRACTING
 TEL: (561)71-9214
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1)PROVIDE NOC RECORDED WITH THE CLERK OF
 COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 104.2.1.2*
 ADDITIONAL INFORMATION REQUIRED, THE
 PERMIT APPLICATION AND PLANS DO NOT HAVE
 THE SAME ADDRESS.
  
 3) THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES
 BETWEEN THE LOTS WHICH COMBINE TO FORM
 'THE SITE'.A 'UNITY OF TITLE' SHALL BE
 RECORDED AT THE COUNTY COURTHOUSE.
 SUBMIT A COPY OF THE RECORDED 'UNITY OF
 OF TITLE' DOCUMENT SO THAT FBC TABLE 600
 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED
 NOT APPLICABLE.
  
  
 4A) FL BLD CODE 104.2.1.2*
 ADDITIONAL INFORMATION REQUIRED, THE
 CODE NOTES INDICATE THAT THE TENANT
 WALLS WILL BE BUILT TO THE U.L. U-465
 BUT THE PLANS DO NOT PROVIDE THE
 INFORMATION OF WHAT MAKES UP THIS
 RATING?
 B) PLANS DO NOT SHOW WHAT WALLS ARE TO
 BE RATED WALLS?
  
 5) 704.2.1.4 CORRIDOR PARTITIONS,
 SMOKE STOP PARTITIONS, HORIZONTAL EXIT
 PART- ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 6) PLANS DO NOT INDICATE ANY OF THE DOOR
 SIZES OR DOOR RATINGS?
  
 7) NOTE THAT THIS IS A HIGH RISE
 BUILDING, 609.2.1 PARTITIONS ARETO BE
 CONSTRUCTED OF NONCOMBUSTIBLE
 MATERIALS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026