2005-01-18 00:00:001. NO ENERGY INFORMATION.
  
 2. FIRST FLOOR SITTING ROOM REQUIRES
 RETURN AIR.FBC/M 2001 601.4 .
  
 3. RETURN AIR OUT OF BEDROOM #2 AND
 #3 MUST BE EQUEAL TO TOTAL SUPPLY DUCTS
 INTO BEDROOM AND CLOSIT/BATHROOM AREA.
 FBC/M 2001 601.4.
  
 4. RETURN AIR OUT OF BEDROOM #1 AND
 OFFICE ARE TRANSFER DUCT, WITCH REQUIRE
 1.5 TIMES THE CROSS SECTINAL AREA OF
 SUPPLY AIR DUCTS.FBC/M 2001 601.4
 EXCEPTION #1 .
  
 5. A/C COMP. UNIT FOR MASTER BEDROOM
 AREA NOT REFLECTED ON PLAN .
  
 6.WINDOW IN BATHROOM #1 MUST CONFORM
 WITH FBC/M 402.3.1 EXCEPTION, WITH MIN.
 OF 3 SQ. FT. OF OPENING SPACE.
 PAT RAFTER 561/805/6725 OR 8056719 .