| 2006-01-06 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04121374 |
| | ADD: 2216 PALM BEACH LAKES BLVD |
| | CONT: K & M COMMERCIAL |
| | TEL: (561)383-2817 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3RD REVIEW |
| | ACTION: DENIED |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. |
| | ***********IMPORTANT*********** |
| | CORALATE PLANS INTO TWO COMPLETE |
| | "STAPLED SETS OF PLANS. |
| | A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A |
| | DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 2) COMMENT#7 FROM THE PEVIOUS REVIEW, |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 3)FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) STRUCTURAL COMPONENTS- TRUSS ABCHORS |
| | B1) ROOF- THERE IS (2) SEPERATE TYPES OF |
| | METAL ROOF REPORTS SUBMITTED. AEICOR |
| | SS-2-21 STANDING METAL ROOF PANEL, |
| | PRESSURES ARE LOW, SEE SYSTEMS |
| | LIMITATION. REMOVE THE REPORTS NOT USED. |
| | B2) ULTRAGUARD PVC WOOD DECK, PICK WHICH |
| | SYSTEM IS TO BE USED SEE PAGES 11-17, |
| | ALSO NOTE ON EACH SYSTEM THE SYSTEM |
| | LIMITATION NOTE MAXIMUM DESIGN PRESSURE |
| | OF 45 PSF AND SYSTEM LIMITATION# 9 NO |
| | INCREASE ALLOWED !!!!!!!!!! SEE TABLE |
| | 1606.2B ZONE# 310 SQ FT= -89PSF |
| | ZONE# 3 20 SQ FT = -73.8PSF REQUIRED!!!! |
| | |
| | 4) PLANS A-12 INDICATE THAT THE WINDOWS |
| | ON THE EAST SIDE HAVE INCREASED.WHEN THE |
| | APPLICANT WENT TO THE BOARD OF |
| | ADJUSTMENT AND APPEAL FOR TABLE 600 AS |
| | WELL AS OPENING PROTECTIVES (705.1.1.2) |
| | THE DESIGN WAS 23% OVER THE ALLOWABLE |
| | OPENING SIZE FOR 5'-10' FROM THE |
| | PROPERTY LINE. WITH THE INCREASE IN |
| | OPENING SIZE THE OVERAGE HAS INCREASED |
| | TO 50% OVER THE ALLOWABLE SIZE AND A 27% |
| | ALLOWABLE OPENINGS APPROVED BY THE |
| | BOARD. |
| | |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |