| 2005-03-21 00:00:00 | PERMIT: 04121254 |
| | ADD: 1318 MERCER AVE |
| | CONT: SOUTHERN CONSTRUCTION |
| | TEL: (561)718-8876 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | |
| | 1) THE PROPOSED BUILDING STRUCTURE |
| | TRANSGRESSES LEGAL BOUNDARY LINES |
| | BETWEEN THE LOTS WHICH COMBINE TO FORM |
| | 'THE SITE'.A 'UNITY OF TITLE' SHALL BE |
| | RECORDED AT THE COUNTY COURTHOUSE. |
| | SUBMIT A COPY OF THE RECORDED 'UNITY OF |
| | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 |
| | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED |
| | NOT APPLICABLE. |
| | IT MAY REQUIRE REPLATTING, SINCE THE |
| | SURVEY INDICATES 6 LOTS THAT WOULD |
| | REQUIRE COMBINING INTO ONE LOT. |
| | |
| | 2) FBC* 105.3RESIDENT INSPECTOR. |
| | SUBMIT INSPECTOR RESUME' AND LICENSE |
| | DOCUMENTS TO HAROLD PISKURA (805-6711), |
| | DIRECTOR OF THE RESIDENT INSPECTOR |
| | PROGRAM.A RESIDENT INSPECTOR PROGRAM |
| | IS REQUIRED, ON THIS PROJECT, DUE TO ONE |
| | OR MORE OF THE FOLLOWING: |
| | - BUILDINGS/ADDITIONS OF TYPE I OR II |
| | CONSTRUCTION |
| | - ANY MAJOR STRUCTURAL ALTERATIONS |
| | - STRUCTURES IN WHICH THE CONCRETE |
| | DESIGN IS BASED ON COMPRESSIVE |
| | STRENGTH (F'C) IN EXCESS OF 3000 PSI |
| | - PILE DRIVING |
| | - BUILDINGS OVER 20,000 SQFT IN AREA |
| | - BUILDINGS OVER 2 STORIES IN HEIGHT |
| | - BUILDING/STRUCTURES OF UNUSUAL DESIGN |
| | OR METHODS OF CONSTRUCTION. |
| | |
| | 3) SINCE THIS BUILDING REQUIRES A |
| | SPECIAL INSPECTOR, SUBMIT (3) SETS OF |
| | ALL DOCUMENTS, PLANS, REPORTS, PRODUCT |
| | APPROVALS, LETTERS AND OR SUBMITTALS . |
| | |
| | |
| | 4) THE PLANS SUBMITTED FROM BUTLER |
| | MANUFACTURING COMPANY SHALL REQUIRE THE |
| | PLANS TO BE SIGNED WITH ORIGINAL |
| | SIGNATURE OF THE P.E., ALL 3 SETS NOT |
| | COPIES OF SIGNATURES.SIGNED & SEALED. |
| | PLANS, SPECIFICATIONS,REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN |
| | PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND |
| | SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| | TO THE DOCUMENT. |
| | FL STATE STAT: 61G15-23.002 ENGINEERS |
| | FL ATATE STAT: 61G16.003 ARCHITECTS |
| | |
| | 5) A2.2 ROOF RACK HEIGHT:THE A?C RACK |
| | DETAIL INDICATES A MINIMUM OF 18" BUT |
| | DOES NOT PROVIDE INFORMATION IF THE UNIT |
| | IS 38" WIDE AS PROVIDED BY TABLE 1511.7. |
| | 1511.7 ROOF MOUNTED MECHANICAL UNITS |
| | SHALL BE MOUNTED ON CURBS RAISED A |
| | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- |
| | FACE, OR WHERE ROOFING MATERIALS EXTEND |
| | BENEATH THE UNIT, ON RAISED EQUIPMENT |
| | SUPPORTS PROVIDING A MINIMUM CLEARENCE |
| | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. |
| | MECH. 301.13 WIND RESISTANCE MECHANICAL |
| | EQUIPMENT, APPLIANCES AND SUP PORTS THAT |
| | ARE EXPOSED TO WIND SHALL BE DESIGNED |
| | AND INSTALLED TO RESIST THE WIND |
| | PRESSURES ON THE EQUIPMENT & THE |
| | SUPPORTS AS DETERMINED IN ACCORDANCE |
| | WITH THE FL BLD CODE. THIS MAY BE ACCOMP |
| | LISHED BY DESIGN OR BY APPLICATION OF |
| | SECTION 301.13.1. |
| | |
| | 6) TABLE 600 ISSUES SEE TYPEIV BLDG |
| | UNPROTECTED, FOOTNOTE (E) UNDER ROOF & |
| | ROOF CEILING ASSEMBLIES. ONLY FIRE |
| | RETARDANT TREATED WOOD CAN BE USED FOR |
| | SHEATHING ON BUILDINGS 2 STORIES OR |
| | LESS. SEE SHEET S0.2 NOTES PLYWOOD ROOF |
| | DECKING, ALSO S2.1 SECTION 5&6 PLEASE |
| | ANNOTE PLANS. |
| | |
| | 7) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 3 COPIES OF THE |
| | PRODUCT APPROVAL FOR THRESHOLD OR |
| | RESIDENT INSPECTOR PROGRAM BUILDING. |
| | |
| | 8) PROVIDE THE PALM BEACH COUNTY IMPACT |
| | FEE RECEIPT, PART OF PERMIT PACKAGE |
| | REQUIREMENTS. |
| | |