| 2005-01-06 00:00:00 | DENIED |
| | |
| | 1.PROJECT DESCRIPTION DOES NOT REFLECT |
| | WORK ON PLANS. A CARPORT CONVERSION TO |
| | GARAGE AND NEW ROOF TRUSSES WERE NOT |
| | MENTIONED. |
| | |
| | 2.SHOW HOW MANY TRUSSES ARE BEING |
| | REPLACED AMD LOCATION OF WORK.THIS |
| | DOES NOT APPEAR TO BE A REPAIR BUT A |
| | DESIGN CHANGE. SUBMIT ROOF FRAMING PLAN |
| | SHOWING TIE DOWNS AND BRACING. |
| | |
| | 3.PRODUCT APPROVALS: |
| | |
| | ONE SET MISSING FOR JELD-WEN EXTERIOR |
| | DOOR.PLEASE SUBMIT SECOND COPY. |
| | |
| | SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR |
| | ROOFING AND STRAPS AND TIE-DOWNS. |
| | ALL PRODUCT APPROVALS REQUIRE THE |
| | FOLLOWING. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 4.VALUATION ON APPLICATION IS TOO |
| | LOW. |
| | REVISE VALUE TO REFLECT ALL MATERIALS |
| | AND LABOR. IF NOT IT WILL BE ADJUSTED |
| | ACCORDING TO MARSHALLS AND SWIFTS |
| | ESTIMATING GUIDE.ADDITIONAL PERMIT |
| | FEES ARE DUE. |
| | |
| | 5.SHOW HOW MUCH ROOFING WILL BE |
| | REPLACED. |
| | |
| | 6.SHEATHING SHALL COMPLY WITH FBC WPB |
| | AMMENDMENTS 2306.1 THICKNESS SHALL BE |
| | 19/32" FOR SHEATHING. PLEASE REVISE ON |
| | PLANS. ALSO CHECK THIS SECTION FOR |
| | SPACING OF FASTENERS. |
| | |
| | 7.NOTES REFER TO CODE ACCORDING TO |
| | PALM BEACH COUNTY, SHOULD BE WEST PALM |
| | BEACH AMMENDMENTS. |
| | |
| | 8.FBC 104.2.1 PERSON RESPOSIBLE FOR |
| | PLANS TO HAVE PRINTED NAME AND SIGNATURE |
| | ON ALL PLANS. |
| | |
| | 9.DETAIL "A" WOOD TO CMU CONNECTION. |
| | PT WOOD REQUIRED AT MASONARY CONTACT. |
| | PLEASE SHOW ON DETAIL. |
| | |
| | 10. SHOW SIZE AND LOCATION OF ATTIC |
| | ACCESS FBC 2309.6 |
| | |
| | 11.CONTRACTOR REQUIRED TO PULL |
| | PERMIT. |
| | THIS IS NOT A PRIMARY RESIDENCE. |
| | SEVERAL PROPERTIES LISTED.FS 489 |
| | |
| | ************ |
| | 12.THIS BUILDING HAS A STOP WORK ORDER |
| | ISSUED ON IT FROM 5-29-03. ROOM ADDITION |
| | BUILT WITH NO PERMITS.THIS PERMIT WILL |
| | NOT BE ISSUED UNTIL A PERMIT HAS BEEN |
| | APPROVED FOR THE EXISTING ROOM |
| | ADDITION. |
| | PLEASE SUBMIT PLANS FOR ROOM ADDITION |
| | AND APPLY FOR A PERMIT. |
| | ************ |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |