| 2005-01-19 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 CHAPTER 1 |
| | FBC-2001 CHAPTER 11 |
| | |
| | 1) SEE BUILDING REVIEW CONCERNING THE |
| | ADDRESS. |
| | 2) SHT A-1 BATHROOM DETAIL. THE |
| | FOLLOWING INFORMATION IS REQUIRED TO |
| | SHOW COMPLIANCE WITH SECTIONS 11-4.16, |
| | 11-4.19, AND 11-4.22: |
| | A) CLEAR FLOOR SPACE 11-4.16.2 |
| | B) FLUSH CONTROLS 11-4.16.5 |
| | C) CLEAR FLOOR SPACE 11-4.19.3 |
| | D) EXPOSED PIPES & SURFACES 11-4.19.4 |
| | E) FAUCETS 11-4.19.6 |
| | F) THE WATER CLOSET SHALL BE 18" FROM |
| | THE CENTERLINE OF THE FIXTURE TO THE |
| | WALL. FIG. 28 |
| | G) THE LAV SHALL CENTER ON THE 30" |
| | MEASURMENT OF THE 30"X48" CLEAR FLOOR |
| | SPACE AND SHALL BE MIN. OF 15" OFF THE |
| | WALL TO THE CENTERLINE OF THE FIXTURE. |
| | 3) MORE INFORMATION IS REQUIRED ON THE |
| | OCCUPANCY. INDICATE TYPE OF BUSINESS |
| | WILL BE IN THE SPACE. - MORE COMMENTS |
| | MAY FOLLOW AFTER COMMENT RESPONSE IS |
| | RECIEVED. SECTION 104.2.1. |
| | 4) SHT P-1 THREE COMPARTMENT SINK IN THE |
| | FOOD PREP AREA SHALL DRAIN INDIRECTLY |
| | INTO AN APPROVED INDIRECT WASTE |
| | RECEPTICAL PER SECTION 802.1.1 & 802.3. |
| | 5) GREASE INTECEPTOR MAY BE REQUIRED. |
| | CONTACT RODNEY COMPO, ENVIRONMENTAL |
| | COMPLIANCE @ (561) 837-4074. WASTE ORD. |
| | NUMBER 2938-96. |
| | |
| | REVIEW BY KEN STEVENS |